PERFORMANCE DU TRANSFERT DE CHALEUR D'UN THERMOSIPHON BIPHASIQUE CHARGE EN TOLUENE.

HEAT TRANSFER PERFORMANCE OF A TOLUENE LOADED TWO-PHASE THERMOSIPHON.

Auteurs : BONTEMPS A.

Type d'article : Article

Résumé

ON A EFFECTUE UNE ETUDE EXPERIMENTALE AVEC UN THERMOSIPHON BIPHASIQUE, FERME, D'UNE DIMENSION IMPORTANTE, ET CORRESPONDANT AU DISPOSITIF UTILISE DANS LES RECUPERATEURS INDUSTRIELS. ON A REALISE DES ESSAIS SUR UN THERMOSIPHON EN ACIER, VERTICAL OU INCLINE, D'UNE LONGUEUR DE 3 M ET D'UN DIAMETRE INTERIEUR DE 27 MM, A DES TEMPERATURES COMPRISES ENTRE 373 ET 573 K (100 ET 300 DEG C) AVEC DU TOLUENE COMME FLUIDE ACTIF. ON A MESURE LA DENSITE DE FLUX THERMIQUE MAXIMALE EN FONCTION DE LA TEMPERATURE POUR DIFFERENTS TAUX DE REMPLISSAGE EN LIQUIDE ET DIFFERENTS ANGLES D'INCLINAISON. ON A DEDUIT LES COEFFICIENTS DE TRANSFERT DE CHALEUR PAR EBULLITION ET CONDENSATION DE CES DONNEES EXPERIMENTALES. ON A OBSERVE QUE LA DENSITE DE FLUX THERMIQUE CRITIQUE DEPENDAIT PEU DU TAUX DE REMPLISSAGE A MOINS QUE LA CHARGE NE SOIT INFERIEURE A 20 %, VALEUR A PARTIR DE LAQUELLE UN DESSECHEMENT LOCAL SE PRODUIT. LA CHARGE OPTIMALE DE REMPLISSAGE ETAIT COMPRISE ENTRE 20 ET 50 %.

Détails

  • Titre original : HEAT TRANSFER PERFORMANCE OF A TOLUENE LOADED TWO-PHASE THERMOSIPHON.
  • Identifiant de la fiche : 1990-1009
  • Langues : Anglais
  • Source : Heat Recov. Syst. CHP - vol. 9 - n. 4
  • Date d'édition : 1989

Liens


Voir d'autres articles du même numéro (6)
Voir la source