Résumé
An experimental study of heat transfer performance in 3D internally finned steel-water heat pipe was carried out in this project. All the main parameters that can significantly influence the heat transfer performance of heat pipe, such as working temperature, heat flux, inclination angle, working fluid fill ratio (defined by the evaporation volume), have been examined. Within the experimental conditions (working temperature 40-95°C, heat flux 5.0-40 kW/m2, inclination angle 2-90°), the evaporation and condensation heat transfer coefficients in 3D internally finned heat pipe are found to be increased by 50-100 and 100-200%, respectively, as compared to the smooth gravity-assisted heat pipe under the same conditions. Therefore, it is concluded that the special structures of 3D-fins on the inner wall can significantly reduce the internal thermal resistance of heat pipe and then greatly enhance its heat transfer performance. [Reprinted with permission from Elsevier. Copyright, 2006].
Détails
- Titre original : Heat transfer performance in 3D internally finned heat pipe.
- Identifiant de la fiche : 2007-1977
- Langues : Anglais
- Source : International Journal of Heat and Mass Transfer - vol. 50 - n. 7-8
- Date d'édition : 04/2007
Liens
Voir d'autres articles du même numéro (4)
Voir la source
Indexation
- Thèmes : Transfert de chaleur
- Mots-clés : Caloduc; Mesure; Transfert de chaleur; Experimentation
-
Experimental investigation on the heat transfer...
- Auteurs : SONG F., EWING D., CHING C. Y.
- Date : 10/2004
- Langues : Anglais
- Source : International Journal of Heat and Mass Transfer - vol. 47 - n. 22
Voir la fiche
-
ETUDE DES REGIMES HYDRODYNAMIQUES D'UN LIQUIDE ...
- Auteurs : SEMENA M. G., KHMELEV Ju. A.
- Date : 1983
- Langues : Russe
- Source : Inzh.-fiz. Zh. - vol. 44 - n. 1
Voir la fiche
-
UNE CAVITE ISOTHERME A BASSE TEMPERATURE UTILIS...
- Auteurs : DUMAS A., GRAZZINI G.
- Date : 1981
- Langues : Italien
- Source : Termotecnica - vol. 35 - n. 12
Voir la fiche
-
Closed loop pulsating heat pipes. Part A: param...
- Auteurs : CHAROENSAWAN P., KHANDEKAR S., GROLL M., et al.
- Date : 11/2003
- Langues : Anglais
- Source : Applied Thermal Engineering - vol. 23 - n. 16
Voir la fiche
-
Operational performance of a cryogenic loop hea...
- Auteurs : MO Q., LIANG J.
- Date : 06/2006
- Langues : Anglais
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 29 - n. 4
- Formats : PDF
Voir la fiche