Performance en termes d'économie d'énergie de conditionneur d'air commercial avec un appareil de pulvérisation attaché à l'unité extérieure.
Energy-saving performance of commercial air-conditioner with spraying apparatus attached to the outdoor unit.
Numéro : pap. n. 274
Auteurs : YOUICHI M., NAGAMATSU K., NAMIWO T., et al.
Résumé
As one way to reduce the electric power consumption of air conditioners in summer, the water spraying apparatus attached to the outdoor unit of air conditioners for business use are commercially available. In this study, in order to evaluate quantitatively the energy-saving performance of the water spraying apparatus, we carried out the detailed partial load performance tests of a packaged type air conditioner (PAC) and multi-split type air conditioners for buildings (MAC) with the water spraying apparatus attached to their outdoor units. As a result, it was found that the effect of water spraying on COP improvement of PAC was the maximum under the rated load condition, while that of MAC depended on its control method of compressors and/or expansion valves. In case of MAC without an intermittent operation under the around half load, the effect of water spraying on COP improvement was maximum under the partial load operation with the cooling load ratios about 80%. On the other hand, in case of MAC with an intermittent operation under the around half load, that was the maximum under the rated load condition.
Documents disponibles
Format PDF
Pages : 8 p.
Disponible
Prix public
20 €
Prix membre*
Gratuit
* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)
Détails
- Titre original : Energy-saving performance of commercial air-conditioner with spraying apparatus attached to the outdoor unit.
- Identifiant de la fiche : 30016091
- Langues : Anglais
- Source : Proceedings of the 24th IIR International Congress of Refrigeration: Yokohama, Japan, August 16-22, 2015.
- Date d'édition : 16/08/2015
- DOI : http://dx.doi.org/10.18462/iir.icr.2015.0274
Liens
Voir d'autres communications du même compte rendu (657)
Voir le compte rendu de la conférence
Indexation
-
Méthode de calcul des sections d'humidification...
- Auteurs : BJALYJ B. I., STEPANOV A. V.
- Date : 1994
- Langues : Russe
- Source : Kholodilnaya Tekhnika - n. 3
Voir la fiche
-
Water-loop self-contained systems in supermarke...
- Auteurs : BAGARELLA G., LAZZARIN R., NORO M.
- Date : 21/08/2016
- Langues : Anglais
- Source : 12th IIR Gustav Lorentzen Conference on Natural Refrigerants (GL2016). Proceedings. Édimbourg, United Kingdom, August 21st-24th 2016.
- Formats : PDF
Voir la fiche
-
Luchtbevochtiging door middel van Micronair ato...
- Date : 10/1997
- Langues : Néerlandais
- Source : Chal. Climats/Warmte Klim. - n. 681
Voir la fiche
-
I am your optimisation guide.
- Auteurs : State of New South Wales and Office of Environment and Heritage 2017
- Date : 07/2015
- Langues : Anglais
- Formats : PDF
Voir la fiche
-
Humidification par atomiseur à buse rotative.
- Date : 02/1997
- Langues : Français
- Source : Chaud Froid Plomb. - vol. 51 - n. 588
Voir la fiche