Performance optimale sur le plan de l'environnement d'un système de refroidisseur refroidi à l'eau avec toutes les configurations de vitesse variable.
Optimal environmental performance of water-cooled chiller system with all variable speed configurations.
Numéro : pap. B1-002
Auteurs : YU F. W., CHAN K. T.
Résumé
This study investigates how the environmental performance of water-cooled chiller systems can be optimized by applying load-based speed control to all the system components. New chiller and cooling tower models were developed using a transient systems simulation program called TRNSYS 15 in order to assess the electricity and water consumption of a chiller plant operating for a building cooling load profile. The chiller model was calibrated using manufacturer’s performance data and used to analyze the coefficient of performance when the design and control of chiller components are changed. The NTU-effectiveness approach was used for the cooling tower model to consider the heat transfer effectiveness at various air-to-water flow ratios and to identify the makeup water rate. Applying load-based speed control to the cooling tower fans and pumps could save an annual plant operating cost by around 15% relative to an equivalent system with constant speed configurations.
Documents disponibles
Format PDF
Pages : 8 p.
Disponible
Prix public
20 €
Prix membre*
15 €
* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)
Détails
- Titre original : Optimal environmental performance of water-cooled chiller system with all variable speed configurations.
- Identifiant de la fiche : 30004932
- Langues : Anglais
- Source : ACRA2010. Asian conference on refrigeration and air conditioning: Tokyo, Japan, June 7-9, 2010.
- Date d'édition : 07/06/2010
Liens
Voir d'autres communications du même compte rendu (107)
Voir le compte rendu de la conférence
Indexation
-
Modeling and comparison of different capacity m...
- Auteurs : INAMPUDI S., BOTTICELLA F., ELBEL S.
- Date : 09/2021
- Langues : Anglais
- Source : 12th International Conference on Compressors and their Systems
- Formats : PDF
Voir la fiche
-
Temperature-dependent thermodynamic chiller mod...
- Auteurs : LIU C. C., CHUNG J. C., CHIANG H. C., et al.
- Date : 07/06/2010
- Langues : Anglais
- Source : ACRA2010. Asian conference on refrigeration and air conditioning: Tokyo, Japan, June 7-9, 2010.
- Formats : PDF
Voir la fiche
-
Energy use characteristics of variable primary ...
- Auteurs : BAHNFLETH W. P., PEYER E. B.
- Date : 17/08/2003
- Langues : Anglais
- Source : 21st IIR International Congress of Refrigeration: Serving the Needs of Mankind.
- Formats : PDF
Voir la fiche
-
Heat exchanger design of liquid-cooled inverter...
- Auteurs : HUNG K. S., CHIANG S. C., CHIANG H. C., et al.
- Date : 07/06/2010
- Langues : Anglais
- Source : ACRA2010. Asian conference on refrigeration and air conditioning: Tokyo, Japan, June 7-9, 2010.
- Formats : PDF
Voir la fiche
-
OPTIMIZATION TECHNIQUES FOR A CENTRIFUGAL CHILL...
- Auteurs : JOHNSON G. A.
- Date : 1985
- Langues : Anglais
Voir la fiche