Recommandé par l'IIF

Performance sur le terrain des pompes à chaleur domestiques pour le chauffage et la production d'eau chaude en Suisse - Partie II : résultats, analyse et optimisation.

Field performance of domestic heat pumps for heating and hot water in Switzerland - Part II: results, analysis and optimization.

Numéro : 2105

Auteurs : KUSTER R., PRINZING M., BERTHOLD M., ESCHMANN M., BERTSCH S.

Résumé

This study presents the development, the methods, and the state of the art of heat pump field trials as they are currently carried out by the Heat Pump Test Center (WPZ) in Buchs SG, Switzerland. In the current study, heat pumps for hydronic heating systems in single family houses within Switzerland have been investigated since 2016. So far, over 20 air-source and geothermal heat pumps have been added to this governmental quality assurance program (Swiss Federal authority EnergieSchweiz). For each heat pump system, more than 40 measured variables are recorded at a time interval of 10 s using calibrated sensors with very low measurement uncertainty.
The aim of this field study is to record the real system efficiency in operation and to draw comparisons with characteristic values from laboratory measurements and manufacturer data. The study presented is divided into two parts. The first part entitled “Technology, Methods and State of the Art of the field studies” focuses on the procedure and measuring technology of field studies performed at WPZ Buchs.
The second part is entitled “Results, Analysis and Optimization of current field studies” and presents meaningful results of the current field study as well as identification and optimization of possible deficiencies in the planning, installation and handling of the investigated heat pump systems.
Heat pumps installed in new and refurbished buildings have been investigated with different system boundaries. In terms of performance, the current study shows an average annual coefficient of performance (SPF) of 3.6 and a span from 3.5 to 3.7 for floor heating and domestic hot water production using air/water heat pumps. Geothermal heat pump systems reach an average annual coefficient of performance of almost 5.
Although the systems are running quite satisfying overall, the results also show considerable differences between the systems as well as typical mistakes in the installation and handling of the heat pumps. A controller that does not work optimally in terms of application and consumption is a frequently found cause of decreased performance.
After evaluating the baseline performance for two years, the systems are optimized to increase performance and avoid poor operation. The collected data is also used to better define guidelines for planner and installers.

Documents disponibles

Format PDF

Pages : 8

Disponible

  • Prix public

    20 €

  • Prix membre*

    15 €

* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)

Détails

  • Titre original : Field performance of domestic heat pumps for heating and hot water in Switzerland - Part II: results, analysis and optimization.
  • Identifiant de la fiche : 30028412
  • Langues : Anglais
  • Sujet : Technologie
  • Source : 2021 Purdue Conferences. 18th International Refrigeration and Air-Conditioning Conference at Purdue.
  • Date d'édition : 05/2021
  • Document disponible en consultation à la bibliothèque du siège de l'IIF uniquement.