PERFORMANCE THERMIQUE D'UN SYSTEME DE SOL A DALLES DE BETON CREUSES POUR LE REFROIDISSEMENT PASSIF.

THERMAL PERFORMANCE OF A HOLLOW CORE CONCRETE FLOOR SYSTEM FOR PASSIVE COOLING.

Auteurs : ZMEUREANU R., FAZIO P.

Type d'article : Article, Synthèse

Résumé

ON PASSE BRIEVEMENT EN REVUE LA DOCUMENTATION PUBLIEE POUR CONCLURE QUE L'ON PEUT OBTENIR DES ECONOMIES D'ENERGIE IMPORTANTES EN UTILISANT LA MASSE DU BATIMENT POUR REFROIDIR CELUI-CI. ON PRESENTE LES RESULTATS D'UNE ETUDE TECHNIQUE PRELIMINAIRE SUR L'UTILISATION DE DALLES CREUSES POUR REDUIRE LES BESOINS DE FROID D'UN IMMEUBLE DE BUREAUX DE MONTREAL TOUT EN MAINTENANT LE CONFORT THERMIQUE DANS DES LIMITES ACCEPTABLES. ON PRESENTE UN MODELE MATHEMATIQUE DU COMPORTEMENT THERMIQUE D'UN LOCAL AVEC SYSTEME DE SOL A DALLES DE BETON CREUSES. LES SIMULATIONS PAR ORDINATEUR POUR UN JOUR CHAUD ET ENSOLEILLE MONTRENT QU'AU COURS DE L'OCCUPATION LE SYSTEME DE SOL A DALLES CREUSES PROCURE LE CONFORT THERMIQUE SANS REFROIDISSEMENT MECANIQUE.

Détails

  • Titre original : THERMAL PERFORMANCE OF A HOLLOW CORE CONCRETE FLOOR SYSTEM FOR PASSIVE COOLING.
  • Identifiant de la fiche : 1989-2045
  • Langues : Anglais
  • Source : Build. Environ. - vol. 23 - n. 3
  • Date d'édition : 1988