Performance thermique d'un thermosiphon fermé diphasique utilisant des nanofluides.

Thermal performance of closed two-phase thermosiphon using nanofluids.

Auteurs : KHANDEKAR S., JOSHI Y. M., MEHTA B.

Type d'article : Article

Résumé

Nanofluids, stabilized suspensions of nanoparticles typically <100 nm in conventional fluids, are evolving as potential enhanced heat transfer fluids due to their improved thermal conductivity, increase in single phase heat transfer coefficient and significant increase in critical boiling heat flux. In this paper, the authors investigate the overall thermal resistance of closed two-phase thermosiphon using pure water and various water based nanofluids (of Al2O3, CuO and laponite clay) as working fluids. They observe that all these nanofluids show inferior thermal performance than pure water. Furthermore, they observe that the wettability of all nanofluids on copper substrate, having the same average roughness as that of the thermosiphon container pipe, is better than that of pure water. A scaling analysis is presented which shows that the increase in wettability and entrapment of nanoparticles in the grooves of the surface roughness cause decrease in evaporator side Peclet number that finally leads to poor thermal performance. [Reprinted with permission from Elsevier. Copyright, 2007].

Détails

  • Titre original : Thermal performance of closed two-phase thermosiphon using nanofluids.
  • Identifiant de la fiche : 2008-1572
  • Langues : Anglais
  • Source : International Journal of thermal Sciences - vol. 47 - n. 6
  • Date d'édition : 06/2008

Liens


Voir la source