Document IIF
Performance transitoire expérimentale d'une pompe à chaleur munie d'une colonne de distillation.
Experimental transient performance of a heat pump equipped with a distillation column.
Auteurs : GEBBIE J. G., JENSEN M. K., DOMANSKI P. A.
Type d'article : Article, Article de la RIF
Résumé
A series of experiments were conducted on a heat pump equipped with a distillation column. The system was operated with R-32 and with a 30/70% by mass mixture of R-32/R-134a to examine the difference between the transient performance trends with a pure fluid (R-32), and those with a zeotropic mixture (R-32/R-134a). Additionally, the effects of varying heat transfer fluid mass flow, compressor speed, and accumulator sump heat input were examined. Each test was 1 h in duration. The heat pump capacities did not generally achieve steady state during the R-32/R-134a tests. Steady state was generally achieved during the R-32 tests. As a percentage of the final (end-of-test) capacity, the rate of capacity increase was greater during the R-32/R-134a tests than during those conducted with the pure fluid. The R-32/R-134a tests exhibited capacity oscillations early in each transient that were not present during the R-32 tests. The results show that circulating refrigerant mass and composition are the primary controlling factors with regard to transient capacity.
Documents disponibles
Format PDF
Pages : 499-505
Disponible
Prix public
20 €
Prix membre*
Gratuit
* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)
Détails
- Titre original : Experimental transient performance of a heat pump equipped with a distillation column.
- Identifiant de la fiche : 2007-0865
- Langues : Anglais
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 30 - n. 3
- Date d'édition : 05/2007
Liens
Voir d'autres articles du même numéro (16)
Voir la source
Indexation
-
Thèmes :
HCFC;
HFC;
Autres applications des pompes à chaleur;
Mélanges - Mots-clés : R134a; Régime transitoire; R22; Pompe à chaleur; Performance; Mélange binaire; Experimentation; Frigorigène; Distillation
-
Experimental pure fluid and binary mixture perf...
- Auteurs : GEBBIE J. G., JENSEN M. K., DOMANSKI P. A., et al.
- Date : 12/2004
- Langues : Anglais
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 27 - n. 8
- Formats : PDF
Voir la fiche
-
Recherches sur les fluides actifs pour les syst...
- Auteurs : GAO P., ZHAO L.
- Date : 01/2006
- Langues : Chinois
- Source : HV & AC - vol. 36 - n. 181
- Formats : PDF
Voir la fiche
-
Flammability and performance test of R-290/R-13...
- Auteurs : PASEK A. D., SUWONO A., UFIE R., et al.
- Date : 29/05/2006
- Langues : Anglais
- Source : 7th IIR-Gustav Lorentzen Conference on Natural Working Fluids (GL2006). Proceedings
- Formats : PDF
Voir la fiche
-
HCFC-22 alternatives for air conditioners and h...
- Auteurs : BIVENS D. B., SHIFLETT M. B., WELLS W. D., SHEALY G. S., YOKOZEKI A. M., PATRON D. M., KOLLIOPOULOS K. A., ALLGOOD C. C., CHISOLM T. E. C.
- Date : 24/06/1995
- Langues : Anglais
- Source : ASHRAE Transactions.
Voir la fiche
-
The performance evaluation of HFC alternative r...
- Auteurs : YAJIMA R., TAIRA S., DOMYO N., MASUDA K.
- Date : 21/09/1994
- Langues : Anglais
- Source : CFCs, the Day After.
- Formats : PDF