Performances thermiques et chute de pression d'échangeurs de chaleur souterrains dotés de tubes en spirale pour une pompe à chaleur géothermique.
Thermal performance and pressure drop of spiral-tube ground heat exchangers for ground-source heat pump.
Auteurs : JALALUDDIN H., MIYARA A.
Type d'article : Article
Résumé
Thermal performance and pressure drop of the spiral-tube GHE were evaluated in this present work. A numerical simulation tool was used to carry out this research. The heat exchange rates per meter borehole depth of the spiral-tube GHE with various pitches and their pressure drops were compared with that of the U-tube GHE. Furthermore, a comparative analysis between a spiral pipe and straight pipe was performed. In comparison with the straight pipe, using the spiral pipe in the borehole increased the heat exchange rate to the ground per meter borehole depth. However, the pressure drop of water flow also increased due to increasing the length of pipe per meter borehole depth and its spiral geometry. The accuracy of the numerical model was verified for its pressure drop with some pressure drop correlations. The heat exchange rate and pressure drop of the GHEs are presented. As an example, the heat exchange rate per meter borehole depth of spiral pipe with 0.05 m pitch in the turbulent flow increased of 1.5 times. Its pressure drop also increased of 6 times. However, from the view point of energy efficiency, using the spiral pipe in the ground-source heat pump system gives a better performance than using the straight pipe. The heat exchange rate and pressure drop are important parameter in design of the ground-source heat pump (GSHP) system.
Détails
- Titre original : Thermal performance and pressure drop of spiral-tube ground heat exchangers for ground-source heat pump.
- Identifiant de la fiche : 30016656
- Langues : Anglais
- Source : Applied Thermal Engineering - vol. 90
- Date d'édition : 05/11/2015
- DOI : http://dx.doi.org/10.1016/j.applthermaleng.2015.07.035
Liens
Voir d'autres articles du même numéro (21)
Voir la source
Indexation
-
Heat dissipation effect on a borehole heat exch...
- Auteurs : DARKWA J., SU W., CHOW D. H. C.
- Date : 10/2013
- Langues : Anglais
- Source : Applied Thermal Engineering - vol. 60 - n. 1-2
Voir la fiche
-
Development and application of ground heat exch...
- Auteurs : ONO E., ARAI Y., SHIOYA M., et al.
- Date : 16/08/2015
- Langues : Anglais
- Source : Proceedings of the 24th IIR International Congress of Refrigeration: Yokohama, Japan, August 16-22, 2015.
- Formats : PDF
Voir la fiche
-
A new ground-coupled heat pump system integrate...
- Auteurs : YOU T., SHI W., WU W., et al.
- Date : 16/08/2015
- Langues : Anglais
- Source : Proceedings of the 24th IIR International Congress of Refrigeration: Yokohama, Japan, August 16-22, 2015.
- Formats : PDF
Voir la fiche
-
Limitations of using uniform heat flux assumpti...
- Auteurs : MALAYAPPAN V., SPITLER J. D.
- Date : 16/06/2013
- Langues : Anglais
- Source : Clima 2013. 11th REHVA World Congress and 8th International Conference on Indoor Air Quality, Ventilation and Energy Conservation in Buildings.
- Formats : PDF
Voir la fiche
-
Wspolczesne rozwiazania konstrukcyjne pionowych...
- Auteurs : WAJMAN M.
- Date : 02/2012
- Langues : Polonais
- Source : Technika Chlodnicza i Klimatyzacyjna - vol. 19 - n. 2
- Formats : PDF
Voir la fiche