Résumé
An analytic equation of the mass flow rate through the bypass of double-inlet pulse tube refrigerators was obtained by an analysis of the pressure drop in the regenerator. The work loss through the bypass is discussed based on this eqution. The work loss ratio at 80 K with an ideal double-inlet is about 50, 30, 20 and 10% when the void volume ratio of the regenerator over the pulse tube is 0.5, 1.0, 2.0, and 4.0, respectively. The analytic results were compared with numerical results.
Détails
- Titre original : Work loss in double-inlet pulse tube refrigerators.
- Identifiant de la fiche : 1999-3332
- Langues : Anglais
- Source : Cryogenics - vol. 38 - n. 8
- Date d'édition : 08/1998
Liens
Voir d'autres articles du même numéro (4)
Voir la source
Indexation
- Thèmes : Cryogénie: applications de faible puissance, cryoréfrigérateurs
- Mots-clés : Tube à pulsation; Énergie; Perte; Cryorefroidisseur
-
A model for parametric analysis of pulse tube l...
- Auteurs : DODSON C., RAZANI A., ROBERTS T.
- Date : 14/06/2006
- Langues : Anglais
Voir la fiche
-
Etat d'avancement d'un nouveau type de réfrigér...
- Auteurs : DAVID M., MARECHAL J. C.
- Date : 1991
- Langues : Français
- Source : J. Phys., 3 - vol. 1 - n. 2
Voir la fiche
-
Experimental study on refrigeration losses in p...
- Auteurs : YUYAMA J., KASUYA M.
- Date : 10/1993
- Langues : Anglais
- Source : Cryogenics - vol. 33 - n. 10
Voir la fiche
-
Study on pulse tube refrigeration. 1. Thermodyn...
- Auteurs : LIANG J., RAVEX A., ROLLAND P.
- Date : 02/1996
- Langues : Anglais
- Source : Cryogenics - vol. 36 - n. 2
Voir la fiche
-
Réfrigérateur à tube pulsé et double admission ...
- Auteurs : INADA T., NISHIO S., OHTANI Y.
- Date : 1995
- Langues : Japonais
- Source : Cryogenics/ Cryog. Eng. - vol. 30 - n. 10
Voir la fiche