Pompe à chaleur à compression utilisant un mélange eau-éthanol comme fluide actif. Caractéristiques du cycle à partir de l'analyse d'un diagramme.

[In Japanese. / En japonais.]

Auteurs : ENDO N., YABE A., YAMASHITA I.

Type d'article : Article

Résumé

The working fluid temperature level was set below 100 °C. In the low temperature region the pressure of the suction gas is low and the influence of mechanical loss of the compressor on COP will be large. The relations of COPs and mechanical loss of compressor has been made clear on the ethanol mol fraction range (0 to 1). The water-ethanol mixture cycle can increase COP and lower the working temperature compared with a water cycle. Another effect of adding ethanol is to decrease the irreversible loss at the heat exchangers. As the water-ethanol mixture is a non-azeotropic mixture, the temperature changes in two-phase regions. This characteristic is valid when a secondary coolant is used.

Détails

  • Titre original : [In Japanese. / En japonais.]
  • Identifiant de la fiche : 2002-3191
  • Langues : Japonais
  • Source : Transactions of the Japan Society of Refrigerating and Air Conditioning Engineers - vol. 18 - n. 3
  • Date d'édition : 2001