Document IIF
Pompe à chaleur à détente directe utilisant un frigorigène à faible PRP et à fort glissement.
Direct expansion heat pump using high glide low GWP refrigerant.
Numéro : 0689
Auteurs : SHEN B., LI Z., WAN H., MOTTA S. Y., GLUESENKAMP K.
Résumé
Next generation of refrigerants require drastically lower global warming potential (GWP). The refrigerant mixtures, with a GWP < 150, e.g., R-457A, etc., tend to have significant temperature glide, which prefer multi-row, cross counter flow configuration. Typical heat pump operation reverses the refrigerant flow direction, compared to the air flow, from cooling mode to heating mode. It is difficult to configurate cross counter-flow heat exchangers in heat pumps. We invented an innovative configuration, having check valve assembly to maintain uniform cross counter flow configuration in both cooling and heat modes, which optimizes the performance of a high temperature slide refrigerant mixture, i.e. R-457A. Based on it, we developed a laboratory prototype, using a 2-stage compressor, achieved a cooling SEER (cooling seasonal energy efficiency rating) of 16.0 (cooling seasonal COP of 4.69) and a heating HSPF (heating seasonal performance factor) > 9.5 (heating seasonal COP of 2.78). The unit was tested in an extensive ambient condition, heating operation from 5˚F to 62˚F (-15˚C to 16.7˚C); cooling operation from 82˚F to 95˚F (27.8˚C to 35˚C). The paper will introduce the system configuration, heat exchanger dimensions and laboratory investigations.
Documents disponibles
Format PDF
Pages : 12
Disponible
Prix public
20 €
Prix membre*
Gratuit
* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)
Détails
- Titre original : Direct expansion heat pump using high glide low GWP refrigerant.
- Identifiant de la fiche : 30031452
- Langues : Anglais
- Sujet : Technologie
- Source : Proceedings of the 26th IIR International Congress of Refrigeration: Paris , France, August 21-25, 2023.
- Date d'édition : 21/08/2023
- DOI : http://dx.doi.org/10.18462/iir.icr.2023.0689
Liens
Voir d'autres communications du même compte rendu (491)
Voir le compte rendu de la conférence
Indexation
-
Performance comparison of an indoor unit of a h...
- Auteurs : VASU A., CHANG Y. S.
- Date : 08/2025
- Langues : Anglais
- Source : 1st IIR International Conference on Refrigeration Adapting to Rising Temperatures
- Formats : PDF
Voir la fiche
-
Cálculo del rendimiento estacional de bombas de...
- Auteurs : SIERES J., ORTEGA I., CERDEIRA F., ALVAREZ E., SANTOS J. M.
- Date : 04/2022
- Langues : Espagnol
- Source : XI Congreso Ibérico y IX Congreso Iberoamericano de Ciencias y Técnicas del Frío, CYTEF 2022.
- Formats : PDF
Voir la fiche
-
Optimized design of heat exchangers for "revers...
- Auteurs : BIGOT G., PALANDRE L., CLODIC D.
- Date : 25/07/2000
- Langues : Anglais
- Source : Proceedings of the 2000 International Refrigeration Conference at Purdue.
Voir la fiche
-
Diseño de una bomba de calor de 8 kW con foco d...
- Auteurs : MARCHANTE-AVELLANEDA J., CORBERÁN J. M., CAZORLA-MARÍN A., et al.
- Date : 19/06/2018
- Langues : Espagnol
- Source : CYTEF 2018. IX Congreso Ibérico y VII Congreso Iberoamericano de Ciencias y Técnicas del Frío, Valencia, España, 19-21 junio 2018.
- Formats : PDF
Voir la fiche
-
Thermodynamic analysis of a novel high-temperat...
- Auteurs : MATEU-ROYO C., NAVARRO-ESBRÍ J., MOTA BABILONI A., et al.
- Date : 24/08/2019
- Langues : Anglais
- Source : Proceedings of the 25th IIR International Congress of Refrigeration: Montréal , Canada, August 24-30, 2019.
- Formats : PDF
Voir la fiche