Document IIF

Pompe a chaleur a propane et a faible charge : conception et essais en laboratoire.

Propane heat pump with low refrigerant charge: design and laboratory tests.

Auteurs : FERNANDO P., PALM B., LUNDQVIST P., et al.

Type d'article : Article, Article de la RIF

Résumé

Independently of the choice of refrigerant, environmental and or safety issues can be minimized by reducing the amount of refrigerant charge per heat pump or refrigeration system. In the investigation reported here, a laboratory test rig was built, simulating a water-to-water heat pump with a heating capacity of 5 kW. The system was designed to minimize the charge of refrigerant mainly by use of mini-channel aluminium heat exchangers. It was shown that the system could be run with 200 g of propane at typical Swedish operating conditions without reduction of the COP compared to a traditional design. Additional charge reduction is possible by selecting proper compressor lubrication oils or by using a compressor with less lubrication oil.

Documents disponibles

Format PDF

Pages : 761-773

Disponible

  • Prix public

    20 €

  • Prix membre*

    Gratuit

* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)

Détails

  • Titre original : Propane heat pump with low refrigerant charge: design and laboratory tests.
  • Identifiant de la fiche : 2005-0434
  • Langues : Anglais
  • Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 27 - n. 7
  • Date d'édition : 11/2004

Liens


Voir d'autres articles du même numéro (9)
Voir la source