Possibilité d'utilisation d'un mélange de frigorigènes zéotropiques comme frigorigène dans les pompes à chaleur destinées à la production d'eau chaude.
Potential of non-azeotropic refrigerant mixture as working refrigerant in hot water heat pumps.
Auteurs : SMIT F. J., MEYER J. P.
Résumé
The refrigerant that is mostly used in hot water heat pumps is R22. It supplies hot water at temperatures of 60 to 65 deg C. In this study it is theoretically shown that a non-azeotropic refrigerant mixture of R22 and R142b has the potential to increase the COP, reduce the pressure ratio of the compressor, maintain chemical stability of refrigerant and lubrication oil, increase heating capacity and display the feature of varying the heating capacity with load.
Détails
- Titre original : Potential of non-azeotropic refrigerant mixture as working refrigerant in hot water heat pumps.
- Identifiant de la fiche : 1999-3407
- Langues : Anglais
- Source : CLIMA 2000, Brussels 1997, August 30 to September 2, Congress Palace.
- Date d'édition : 08/1997
- Document disponible en consultation à la bibliothèque du siège de l'IIF uniquement.
Liens
Voir d'autres communications du même compte rendu (45)
Voir le compte rendu de la conférence
Indexation
-
Thèmes :
Autres équipements de conditionnement d'air;
Mélanges - Mots-clés : Eau chaude; Pompe à chaleur; Mélange zéotropique; Frigorigène
-
INVESTIGATIONS WITH APPLICATION OF REFRIGERANT ...
- Auteurs : MACZEK K., SCHNOTALE J.
- Date : 17/09/1986
- Langues : Anglais
Voir la fiche
-
Development of an air conditioning and hot wate...
- Auteurs : KATO M., KOBAYASHI K., KUDO M., et al.
- Date : 17/02/2010
- Langues : Anglais
- Source : Measures to address climate change. 2010 International Symposium on Next-generation Air Conditioning and Refrigeration Technology: February 17-19, Tokyo, Japan.
- Formats : PDF
Voir la fiche
-
ASHP with non-azeotropic refrigerant and resear...
- Auteurs : WANG R. X., LI H. Q., LI A. G., et al.
- Date : 17/09/2002
- Langues : Anglais
- Formats : PDF
Voir la fiche
-
APPLICATION OF NON-AZEOTROPIC REFRIGERANT MIXTU...
- Auteurs : NOMURA H.
- Date : 05/08/1986
- Langues : Anglais
- Source : Progress in the design and construction of refrigeration systems.
- Formats : PDF
Voir la fiche
-
Thermodynamic performance assessment of carbon ...
- Auteurs : DAI B., LI M., DANG C., et al.
- Date : 02/08/2014
- Langues : Anglais
- Source : 11th IIR Gustav Lorentzen Conference on Natural Refrigerants (GL2014). Proceedings. Hangzhou, China, August 31-September 2, 2014.
- Formats : PDF
Voir la fiche