Résumé
In this paper, the influence of the climate on the optimal configuration of a façade module is investigated. An integrated modelling approach is used, coupling thermal and lighting simulations, in a total energy perspective. In fact, the “optimal configuration” of the façade module is the one that minimizes the sum of the energy demand for heating, cooling and artificial lights. solution is searched, by means mean of numerical simulations, in four locations in Europe, by changing the percentage of transparent surface (window-to-wall ratio). All the four main orientations are investigated, and robustness of the solutions is also checked against different HVAC system efficiencies and in buildings with different surface area over volume ratios (SA:V). The results demonstrate that each climate requires a dedicated optimized solution, though it is shown that the façade configuration has a moderate impact on the total energy need of the building – provided that best-available technologies are adopted. It is also shown that, in climates where cooling energy demand is dominant (Athens and Rome), the influence of the building shape (SA:V) on the total energy demand is relatively low, but it has a certain effect on the optimal configuration of the façade module. In these climates, a “wrong” configuration of the façade module may determine an increase in the total energy consumption of about 20%. On the contrary, in climates where the cooling energy demand is not dominant (Frankfurt and Oslo), the shape of the building affects the total energy demand, but the optimal solution is almost independent from the shape of the building. Furthermore, in these conditions, the façade configuration has a less relevant influence on the total energy need.
Documents disponibles
Format PDF
Pages : 8 p.
Disponible
Prix public
20 €
Prix membre*
15 €
* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)
Détails
- Titre original : Optimal transparent percentage in façade modules for office buildings in different European climates.
- Identifiant de la fiche : 30005782
- Langues : Anglais
- Source : EuroSun 2012: solar energy for a brighter future. ISES-Europe solar conference. Conference proceedings: Rijeka, Croatia, 18-20 September 2012.
- Date d'édition : 18/09/2012
Liens
Voir d'autres communications du même compte rendu (44)
Voir le compte rendu de la conférence
Indexation
- Thèmes : Conditionnement d'air pour le confort
- Mots-clés : Bureau; Immeuble; Refroidissement; Modélisation; Europe; Énergie solaire; Éclairage; Construction; Chauffage; Climat
-
ENERGY PERFORMANCE AND SAVINGS POTENTIALS WITH ...
- Auteurs : ARASTEH D.
- Date : 1985
- Langues : Anglais
Voir la fiche
-
A study on the integrated control system as an ...
- Auteurs : KANG K., PARK J., KANG G., et al.
- Date : 16/06/2013
- Langues : Anglais
- Source : Clima 2013. 11th REHVA World Congress and 8th International Conference on Indoor Air Quality, Ventilation and Energy Conservation in Buildings.
- Formats : PDF
Voir la fiche
-
Limits and artefacts of reflective imaging goni...
- Auteurs : KARAMATA B., ANDERSEN M.
- Date : 18/09/2012
- Langues : Anglais
- Source : EuroSun 2012: solar energy for a brighter future. ISES-Europe solar conference. Conference proceedings: Rijeka, Croatia, 18-20 September 2012.
- Formats : PDF
Voir la fiche
-
Solar irradiance modelling and uncertainty on b...
- Auteurs : PERNIGOTTO G., PRADA A., BAGGIO P., et al.
- Date : 11/07/2016
- Langues : Anglais
- Source : 2016 Purdue Conferences. 4th International High Performance Buildings Conference at Purdue.
- Formats : PDF
Voir la fiche
-
EVASOLK – Evaluation of solar cooling in compar...
- Auteurs : WIEMKEN E., ELIAS A. R. P., NIENBORG B., et al.
- Date : 18/09/2012
- Langues : Anglais
- Source : EuroSun 2012: solar energy for a brighter future. ISES-Europe solar conference. Conference proceedings: Rijeka, Croatia, 18-20 September 2012.
- Formats : PDF
Voir la fiche