Prédominance des moisissures cultivables véhiculées par l'air dans 100 immeubles de bureaux aux Etats-Unis dans l'étude et l'évaluation (BASE) des bâtiments.
Prevalence of culturable airborne fungi in 100 US office buildings in the building assessment survey and evaluation (BASE) study.
Auteurs : MACHER J. M., TSAI F. C., BURTON L. E., et al.
Résumé
The paper presents preliminary analyses of the data on airborne fungi collected in 100 US office buildings in the BASE study. There was agreement between the two methods used to identify fungi (i.e. culture and microscopic examination), but each approach provided information the other did not. Almost all fungi were found more often in samples of outdoor than indoor air and more often in summer than winter in both locations. An association with summer humidity was observed for water-requiring (hydrophilic) and leaf-surface (phylloplane) fungi indoors. No effect of summer temperature was found. Leaf-surface, soil, and potentially toxigenic fungi were identified in more outdoor samples in regions with warmer winters, whereas leaf-surface, soil, and water-requiring fungi were more prevalent indoors in regions with moderate vs. warmer or cooler winters. These differences suggest that investigators must consider the season in which they collect samples and a building's ventilation patterns.
Détails
- Titre original : Prevalence of culturable airborne fungi in 100 US office buildings in the building assessment survey and evaluation (BASE) study.
- Identifiant de la fiche : 2005-1452
- Langues : Anglais
- Source : IAQ 2001. Moisture, microbes and health effects: indoor air quality and moisture in buildings [CD-ROM].
- Date d'édition : 2002
Liens
Voir d'autres communications du même compte rendu (9)
Voir le compte rendu de la conférence
Indexation
- Thèmes : Qualité de l'air intérieur
- Mots-clés : Spore; Bureau; Moisissure; Ventilation; Qualité de l'air; Enquête; Conditionnement d'air; Climat
-
Performance of ductless personalized ventilatio...
- Auteurs : DALEWSKI M., KHALIFA H. E., MELIKOV A. K.
- Date : 16/06/2013
- Langues : Anglais
- Source : Clima 2013. 11th REHVA World Congress and 8th International Conference on Indoor Air Quality, Ventilation and Energy Conservation in Buildings.
- Formats : PDF
Voir la fiche
-
Etude de la qualité de l'air sur une population...
- Auteurs : MAINA G., SONNINO A., CERINA G., MORETTO N., et al.
- Date : 1994
- Langues : Français
- Source : Arch. Mal. prof. - vol. 55 - n. 6
Voir la fiche
-
Thermal comfort and air quality in eight office...
- Auteurs : ROWE D. M., WILKE S. E.
- Date : 07/1995
- Langues : Anglais
- Source : AIRAH J. - vol. 49 - n. 7
Voir la fiche
-
FRESHNESS, VENTILATION AND TEMPERATURE IN OFFICES.
- Auteurs : CROOME D. J., ROLLASON D. H.
- Date : 06/1988
- Langues : Anglais
Voir la fiche
-
Mécanisme de la structure de l'écoulement d'air...
- Auteurs : LIM E., SAGARA K., YAMANAKA T., et al.
- Date : 12/2008
- Langues : Japonais
- Source : Transaction of the Society of Heating, Air-conditioning and Sanitary Engineers of Japan - n. 141
Voir la fiche