Prévision de la chute de pression due au frottement lors de l'écoulement de frigorigènes à l'intérieur de tubes horizontaux : comparaison avec une base de données expérimentale.

Prediction of frictional pressure drop during flow boiling of refrigerants in horizontal tubes: comparison to an experimental database.

Auteurs : REVELLIN R., HABERSCHILL P.

Type d'article : Article, Article de la RIF

Résumé

An experimental frictional pressure drop database for smooth tubes including 485 points from the literature is compared to four well-known correlations and also to the phenomenological model by Moreno Quibén and Thome. This model is new and has never been compared to those experimental data. The Grönnerud correlation and the flow pattern based two-phase frictional pressure drop model by Moreno Quibén and Thome display the best prediction. Seventy-four percent of the data are predicted by the latter model within a plus or minus 30% error band. Furthermore, the model by Moreno Quibén and Thome predicts a maximum pressure drop before the annular-to-dry out transition, i.e. as usually in the annular flow regime. An explicit expression (never proposed before) for the vapour quality corresponding to the maximum pressure drop is developed here. Based on this maximum and on the pressure drop for liquid and vapour, a simple linear function is developed for predicting the frictional pressure drop. This method presents the best accuracy and predicts almost 86% of the data within a plus or minus 30% error band. This method does not include any new empirical parameters and can be used for a wide range of experimental conditions. Furthermore, the experimental data were also segregated into flow regimes and compared to each individual prediction method. The linear approach presents the best statistics for each flow regime. In addition, an experimental frictional pressure drop database for helically microfinned tubes including 673 points from the literature is also compared to three existing correlations. The Kuo and Wang correlation presents the best statistics, predicting almost 85% of the data within a plus or minus 30% error band.

Documents disponibles

Format PDF

Pages : 487-497

Disponible

  • Prix public

    20 €

  • Prix membre*

    Gratuit

* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)

Détails

  • Titre original : Prediction of frictional pressure drop during flow boiling of refrigerants in horizontal tubes: comparison to an experimental database.
  • Identifiant de la fiche : 2009-0545
  • Langues : Anglais
  • Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 32 - n. 3
  • Date d'édition : 05/2009