Prévision du débit d'air dans l'environnement thermique d'une installation souterraine. 2. Simulation du débit d'air isothermique dans une station de métro utilisant des modèles microscopique et macroscopique couplés.

[In Japanese. / En japonais.]

Auteurs : FUKUYO K., SHIMODA Y., MIZUNO M.

Type d'article : Article

Résumé

Airflow in subway systems is usually predicted by microscopic models based on the assumption that airflow is one dimensional. Three dimensional models require heavy computational loads. A practical solution is to apply a microscopic model to the target space and a macroscopic model to the surrounding space. In this paper, a two-way model is developed. There is little difference in the results between the one-way and two-way models. With the exception of the case where the structure of a station causes high airflow impedance, it is convenient to apply the one-way model to ordinary types of subway stations concerning computational load.

Détails

  • Titre original : [In Japanese. / En japonais.]
  • Identifiant de la fiche : 1998-3148
  • Langues : Japonais
  • Source : Transaction of the Society of Heating, Air-conditioning and Sanitary Engineers of Japan - n. 66
  • Date d'édition : 07/1997
  • Document disponible en consultation à la bibliothèque du siège de l'IIF uniquement.

Liens


Voir d'autres articles du même numéro (4)
Voir la source