Principes dynamiques fondamentaux des réfrigérateurs Stirling split.

Basic dynamics of split Stirling refrigerators.

Auteurs : WAELE A. T. A. M. de, LIANG W.

Type d'article : Article

Résumé

The basic features of the split Stirling refrigerator, driven by a linear compressor, are described. Friction of the compressor piston and of the regenerator, and the viscous losses due to the gas flow through the regenerator matrix are taken into account. The temperature at the cold end is an input parameter. The general equations are derived which are subsequently treated in the harmonic approximation. Examples are given of application of the relations for describing optimum-performance conditions as well as the interrelationship between cooler and heat-engine operation. [Reprinted with permission from Elsevier. Copyright, 2008].

Détails

  • Titre original : Basic dynamics of split Stirling refrigerators.
  • Identifiant de la fiche : 2008-2388
  • Langues : Anglais
  • Source : Cryogenics - vol. 48 - n. 9-10
  • Date d'édition : 09/2008

Liens


Voir d'autres articles du même numéro (6)
Voir la source