Document IIF
Prochaine génération des systèmes frigorifiques efficaces au NH3.
Next generation of efficient NH3 refrigeration systems.
Numéro : pap. 218
Auteurs : PACHAI A. C.
Résumé
With the introduction of variable speed drives (VSD) it has only been a matter of time before this technology was fully integrated into refrigeration equipment. The traditional compressors could be adapted to the use of VSD provided the frequencies at which the compressors would vibrate too much were skipped. The use of adapted VSD could also create some discussion about how best to utilize the capacity regulation without causing mechanical stress in the system. With the introduction of compressors specifically designed for the use of VSD ensures many problems – big and small – have been solved. In the past many compressors were using VSD with both the traditional cylinder engaging/disengaging in reciprocating compressors or capacity slide in screw compressors. This could cause vibrations in some speed ranges; perhaps only in certain combinations of speed and capacity. In order to avoid vibration problems the controller would skip some frequencies meaning that the compressor
would not run at these frequencies for a prolonged time, but only pass through them as quickly as the motor would allow. The new compressors - born for VSD- do not have this problem because they are without the traditional capacity controls and, instead of being adapted to VSD, are designed for it from the beginning. Vibrations can cause all sorts of damage to the compressor or pipe system and even a major failure or reduced lifetime. The possibility of saving money on the power consumption is always interesting for end users. VSD provides an opportunity of adjusting the actual compressor capacity to the actual cooling load. One advantage of the VSD system is the constant adjustment of the capacity and power consumption to the load, but another often overlooked advantage is that the service intervals are extended because the mechanical wear on the moving parts is less when the compressor is at the slower speed. It is, therefore, beneficial to incorporate this parameter into the compressor control and calculate the extended time until the next service based on the actual operating speed (among other parameters), instead of the traditional way of only looking at a fixed period of running hours. Now one may say that there is nothing new in this technology since it has been known for some years now. That is also a kind of truth but the systems looked at here the first open type compressor sets especially optimised for ammonia. Other companies and contractors have long been working with the technology using semi-hermetic or hermetic compressors. Using open type compressors has its own challenges because you are connecting two units with a coupling. However, many of the conclusions and issues are the same for any other refrigerant.
Documents disponibles
Format PDF
Pages : 9 p.
Disponible
Prix public
20 €
Prix membre*
Gratuit
* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)
Détails
- Titre original : Next generation of efficient NH3 refrigeration systems.
- Identifiant de la fiche : 30012108
- Langues : Anglais
- Source : 3rd IIR International Conference on Sustainability and the Cold Chain. Proceedings: London, UK, June 23-25, 2014
- Date d'édition : 23/06/2014
Liens
Voir d'autres communications du même compte rendu (87)
Voir le compte rendu de la conférence
Indexation
-
Energy efficiency of small refrigeration system...
- Auteurs : NOVAK L.
- Date : 25/06/2012
- Langues : Anglais
- Source : 10th IIR-Gustav Lorentzen Conference on Natural Working Fluids (GL2012). Proceedings. Delft, The Netherlands, June 25-27, 2012.
- Formats : PDF
Voir la fiche
-
Système de conservation d'énergie appliqué aux ...
- Auteurs : HASEGAWA Y., UEDA K., MATSUO M., et al.
- Date : 03/2011
- Langues : Japonais
- Source : Refrigeration - vol. 86 - n. 1001
Voir la fiche
-
Frequency converters with a field bus: an oppor...
- Auteurs : WURM H. P.
- Date : 17/10/2000
- Langues : Anglais
- Source : Symposium 2000. Cost savings and improved environmental protection by means of more energy efficient refrigeration/air conditioning systems.
Voir la fiche
-
Test bench for comparative measurement of energ...
- Auteurs : BENAMER A., CLODIC D.
- Date : 19/09/1999
- Langues : Anglais
- Source : 20th International Congress of Refrigeration: Refrigeration into the Third Millennium.
- Formats : PDF
Voir la fiche
-
Application of a lumped model for predicting en...
- Auteurs : NAVARRO-ESBRÍ J., GINESTAR D., BELMAN J. M., et al.
- Date : 04/2010
- Langues : Anglais
- Source : Applied Thermal Engineering - vol. 30 - n. 4
Voir la fiche