Production d'air à faible point de rosée par une roue déshydratante à adsorption et son concept de conception/fonctionnement.
Low dew point air production by adsorptive desiccant rotor and its design/operating concept.
Numéro : pap. n. 102
Auteurs : AYAME H., TSUJIGUCHI T., KODAMA A., et al.
Résumé
A design/operation improvement method of low dew point air supply system using a desiccant rotor was studied by numerical simulation. First, the angular distributions of air humidity and temperature developed at each outlet of a desiccant rotor were carefully measured and discussed for the help in construction of mathematical model and verification of the simulation results. Next, a modified simulation model was developed taking the physical characteristics of the rotor especially at the target low humidity region into account. As a result, good agreement between experimental and calculated values was obtained. Then, influences of the principal operating parameters on the process performance were investigated by means of the numerical simulation and the relations between principal operating parameters were summarized in some diagrams. These diagrams can be applied for optimization of the system operation at part load conditions.
Documents disponibles
Format PDF
Pages : 9 p.
Disponible
Prix public
20 €
Prix membre*
15 €
* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)
Détails
- Titre original : Low dew point air production by adsorptive desiccant rotor and its design/operating concept.
- Identifiant de la fiche : 30013754
- Langues : Anglais
- Source : International sorption heat pump conference (ISHPC2014), College Park, United States, March 31-April 2, 2014.
- Date d'édition : 02/03/2014
Liens
Voir d'autres communications du même compte rendu (125)
Voir le compte rendu de la conférence
-
Grey-box modelling and in situ experimental ide...
- Auteurs : APRILE M., MOTTA M.
- Date : 03/2013
- Langues : Anglais
- Source : Applied Thermal Engineering - vol. 51 - n. 1-2
Voir la fiche
-
Desiccant dewpoint cooling system independent o...
- Auteurs : BELLEMO L., ELMEGAARD B., MARKUSSEN W. B., et al.
- Date : 16/08/2015
- Langues : Anglais
- Source : Proceedings of the 24th IIR International Congress of Refrigeration: Yokohama, Japan, August 16-22, 2015.
- Formats : PDF
Voir la fiche
-
A comprehensive review of low dew-point desicca...
- Auteurs : XU Y., CHEN L.
- Date : 12/2024
- Langues : Anglais
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 168
- Formats : PDF
Voir la fiche
-
Experimental investigations on desiccant wheels.
- Auteurs : EICKER U., SCHÜRGER U., KÖHLER M., et al.
- Date : 09/2012
- Langues : Anglais
- Source : Applied Thermal Engineering - vol. 42
Voir la fiche
-
Open-cycle absorption and desiccant technology.
- Auteurs : GROSSMAN G.
- Date : 06/04/2011
- Langues : Anglais
- Source : Sources/sinks Alternative to the Outside Air for Heat Pump and Air-conditioning Techniques (Alternative Sources - AS), Padua, Italy, April 5-7, 2011. / International Sorption Heat Pump Conference (ISHPC11), Padua, Italy, April 6-8, 2011.
- Formats : PDF
Voir la fiche