Résumé
This paper gives a balanced load distribution between evaporative cooling and radiant cooling based on the engineering design of the composite air-conditioning system advanced by the authors. It tests the fresh air system, high temperature chilled water system and indoor temperature and humidity environment on the composite test-bed under summer air-conditioning conditions. The test results show that when the air-conditioning systems run in the summer of mid-humidity area whose supply water temperature is 19°C and supply air temperature is 17°C, the maximum temperature difference is less than 2°C at all sections between 0.1 and 1.1 m above the floor, and the indoor temperature is about 26 to 26.5°C at 1.1 m. The experimental results also show that the gradient of temperature is less than 2°C/m between the heights of 0.1 and 1.1 m and is less than 1°C/m between 1.1 and 2.7 m, meanwhile indoor relative humidity is in a range of 53.3 to 65.4%. So the experimental results illustrate that the composite air-conditioning system can meet thermal comfort for the occupants. In addition, the mean surface temperature of radiant cooling panel is 21.75 to 21.9°C, which avoids the risk of condensation, because the ceiling surface temperature is higher than the dew point temperature.
Documents disponibles
Format PDF
Pages : pp. 34-41
Disponible
Prix public
20 €
Prix membre*
15 €
* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)
Détails
- Titre original : [In Chinese. / En chinois.]
- Identifiant de la fiche : 2010-1243
- Langues : Chinois
- Source : HV & AC - vol. 39 - n. 228
- Date d'édition : 09/2009
Liens
Voir d'autres articles du même numéro (8)
Voir la source
Indexation
-
Theoretical and experimental study on the tubul...
- Auteurs : HUANG X., WANG Y., WU J.
- Date : 21/05/2006
- Langues : Anglais
- Source : ACRA-2006. Proceedings of the 3rd Asian conference on refrigeration and air conditioning.
Voir la fiche
-
Description and experimental results of a semi-...
- Auteurs : VELASCO GÓMEZ E., REY MARTÍNEZ F. J., VARELA DIEZ F., et al.
- Date : 08/2005
- Langues : Anglais
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 28 - n. 5
- Formats : PDF
Voir la fiche
-
Effects of evaporation water flow rate on the c...
- Auteurs : CHOO H. S., LEE K. S., LEE D. Y.
- Date : 21/05/2006
- Langues : Anglais
- Source : ACRA-2006. Proceedings of the 3rd Asian conference on refrigeration and air conditioning.
Voir la fiche
-
Characterization of a semi-indirect evaporative...
- Auteurs : HERRERO MARTÍN R.
- Date : 07/2009
- Langues : Anglais
- Source : Applied Thermal Engineering - vol. 29 - n. 10
Voir la fiche
-
Simultaneous heat and mass transfer in a wetted...
- Auteurs : ZHANG F., BOCK J., JACOBI A. M., et al.
- Date : 16/07/2012
- Langues : Anglais
- Source : 2012 Purdue Conferences. 14th International Refrigeration and Air-Conditioning Conference at Purdue.
- Formats : PDF
Voir la fiche