Recherche sur l'amélioration de la performance d'une pompe à chaleur air-eau.

[In Chinese. / En chinois.]

Auteurs : ZHEN B., LIU Z. H., WANG Q., et al.

Type d'article : Article

Résumé

The problems for heat pumps operating at low ambient temperatures were analyzed. A by-pass capillary tube was added on the discharge pipe behind the four-way valve and a tube was added in an accumulator in a heat pump system to solve the problem. The minimum heat transfer area of the tube for subcooling and the optimal length range of the by-pass capillary tube were determined. The experiment results show that heat output of the improved heat pump increased greatly at low ambient temperatures.

Documents disponibles

Format PDF

Pages : 12-17

Disponible

  • Prix public

    20 €

  • Prix membre*

    15 €

* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)

Détails

  • Titre original : [In Chinese. / En chinois.]
  • Identifiant de la fiche : 2007-1280
  • Langues : Chinois
  • Source : Journal of Refrigeration - vol. 28 - n. 1
  • Date d'édition : 02/2007

Liens


Voir d'autres articles du même numéro (6)
Voir la source