Recherches thermodynamiques sur un cycle de stockage d'énergie à contact direct.

[In Chinese. / En chinois.]

Auteurs : ZHANG X. L., LI R. Y., SHU P. C., et al.

Type d'article : Article

Résumé

A direct contact thermal storage system has advantages such as little corrosion, no scaling, higher heat transfer efficiency and small temperature difference. Thermodynamic research on a direct contact thermal storage system was carried out which concluded that the direct contact thermal storage system had a higher COP and exergy efficient than a traditional spiral tube type and its main exergy loss resulted from the compressor. Otherwise, some influences of super heating degree, super cooling degree, and adiabatic efficiency are also discussed.