Document IIF

Récupération de chaleur dans les colonnes de distillation utilisant des cycles de compression-résorption.

Heat recovery in distillation columns using compression-resorption cycles.

Résumé

Distillation columns are generally operated very inefficiently from an energetic point of view. At the bottom, a boiler is required to vaporize the mixture while at the top heat is rejected to the environment. Vapour recompression heat pumps have been very successful in the realization of extremely large energy savings. For larger temperature lifts between top and bottom, the temperature glide in the absorber and desorber of compression-resorption heat pumps reduce the thermodynamic temperature lift and make heat pumps a competitive solution. In this paper the performance of a diabatic column with the resorber of an ammonia-water compression-resorption heat pump integrated in the stripping section of the column and (part) of the desorber in the rectification section will be compared with the performance of an adiabatic column. The conventional boiler/condenser option and the compression resorption and the vapour recompression heat pump options will be investigated. The impact of ammonia-water concentration on performance and operating conditions of compression resorption heat pumps will also be discussed.

Documents disponibles

Format PDF

Pages : 2008-2

Disponible

  • Prix public

    20 €

  • Prix membre*

    Gratuit

* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)

Détails

  • Titre original : Heat recovery in distillation columns using compression-resorption cycles.
  • Identifiant de la fiche : 2009-0420
  • Langues : Anglais
  • Source : 8th IIR-Gustav Lorentzen Conference on Natural Working Fluids (GL2008)
  • Date d'édition : 07/09/2008

Liens


Voir d'autres communications du même compte rendu (132)
Voir le compte rendu de la conférence