Document IIF
Réduction de la charge en frigorigène dans un réfrigérateur pour le transport à basse température grâce à un évaporateur à plaques eutectiques.
Refrigerant charge reduction in low-temperature transport refrigerator with the eutectic plate evaporator.
Auteurs : VAITKUS L., DAGILIS V.
Type d'article : Article, Article de la RIF
Résumé
In the article a problem of refrigerant charge reduction of the transport refrigerating system with eutectic plate evaporator is analysed. Such system generates cold during the night, with the vehicle in the depot, and during the day it operates without access to electricity supply. Due to weight limitations the system is equipped with single-stage compressor, which is normally operated at very low evaporation temperatures (-43 ÷ -45 °C during the crystallization of eutectic mixture) and high compression ratios. At the initial stage of pull-down the temperature of eutectic plates is high and therefore maximum operation pressure (MOP) control is required. Other important features with regard to charge minimization are big thermal inertia and relatively big inner volume of the evaporator. During the research it was found that the refrigerant charge is strongly influenced by a system used for MOP control. The other charge influencing factors were also analysed. Two low charge refrigerators with different evaporator setup and MOP control systems were developed and tested. The refrigerant charge was reduced from 4.1 kg to 2.4 and 2.5 kg of R507 without a negative impact on performance. The possibility of further charge reduction is also discussed. The problem is analysed on the example of eutectic system, but the conclusions apply also to all low-temperature single stage systems with some means of MOP control.
Documents disponibles
Format PDF
Pages : 46-57
Disponible
Prix public
20 €
Prix membre*
Gratuit
* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)
Détails
- Titre original : Refrigerant charge reduction in low-temperature transport refrigerator with the eutectic plate evaporator.
- Identifiant de la fiche : 30012493
- Langues : Anglais
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 47
- Date d'édition : 11/2014
Liens
Voir d'autres articles du même numéro (14)
Voir la source
-
Differential mass evacuation sampling method fo...
- Auteurs : LEE A. J., BACH C. K., BRADSHAW C. R.
- Date : 2022
- Langues : Anglais
- Source : 2022 Purdue Conferences. 19th International Refrigeration and Air-Conditioning Conference at Purdue.
- Formats : PDF
Voir la fiche
-
Comparison of refrigerant charge requirements i...
- Auteurs : ALLYMEHR E., WILL T., SCHNABEL L., SKAUGEN G.
- Date : 01/09/2021
- Langues : Anglais
- Source : 6th IIR Conference on Thermophysical Properties and Transfer Processes of Refrigerants
- Formats : PDF
Voir la fiche
-
Design of reduced charge systems. II. Refrigera...
- Auteurs : PALM B.
- Date : 25/10/2012
- Langues : Anglais
- Source : RCR 2012. 3rd IIR Workshop on Refrigerant Charge Reduction in Refrigerating Systems: Valencia, Spain, October 25-26, 2012.
- Formats : PDF
Voir la fiche
-
Refrigerant charge estimation methods for braze...
- Auteurs : WILL T., SCHNABEL L., KÖHLER J.
- Date : 13/06/2022
- Langues : Anglais
- Source : 15th IIR-Gustav Lorentzen Conference on Natural Refrigerants (GL2022). Proceedings. Trondheim, Norway, June 13-15th 2022.
- Formats : PDF
Voir la fiche
-
On new plate designs for brazed plate heat exch...
- Auteurs : GULLAPALLI V. S.
- Date : 25/10/2012
- Langues : Anglais
- Source : RCR 2012. 3rd IIR Workshop on Refrigerant Charge Reduction in Refrigerating Systems: Valencia, Spain, October 25-26, 2012.
- Formats : PDF
Voir la fiche