Réfrigérateurs à tube à pulsation à contre-courant.

Counter-flow pulse-tube refrigerators.

Résumé

Regenerators in standard pulse-tube refrigerators are expensive, complicated, heavy, and they contribute significantly to the losses in the cooler. In the research, the regenerators are avoided by using two identical GM-type pulse-tube refrigerators operating in opposite phase. The two regenerators are replaced by one counterflow heat exchanger. This system is called the counterflow pulse-tube refrigerator. A special feature of the system is that the pressure wave is generated by a rotating valve at low temperature. The basic principle of the processes in the counterflow pulse-tube refrigerator are discussed and some preliminary experimental results are given.

Détails

  • Titre original : Counter-flow pulse-tube refrigerators.
  • Identifiant de la fiche : 2006-0008
  • Langues : Anglais
  • Source : Proceedings of the nineteenth International Cryogenic Engineering Conference. ICEC 19.
  • Date d'édition : 22/07/2002

Liens


Voir d'autres communications du même compte rendu (71)
Voir le compte rendu de la conférence