Refroidisseur à système à sorption en cascade à chauffage direct.
Neposredno kurjen kaskadni sorpcijski hladilnik./ Direct fired cascading sorption chiller.
Auteurs : SATZGER P., BERLITZ T., ZIEGLER F.
Type d'article : Article
Résumé
Presently available commercial absorption chillers reach COPs of about 1.2. If, for power demand side reasons, cooling by direct-fired absorption chillers is promoted, it is evident that the COP and the PER (primary energy ratio) of absorption chillers must be improved. One promising way to attain this goal is to use high-temperature driving heat, as it is always available when fossil fuels are being burned. Multi-effect cycles make it possible to use these high temperatures efficiently, but the heavy corrosion problems with ordinary sorption liquids have in the past prevented the realisation of these cycles. In cascading cycles, which allow to employ different working pairs in the different cycles, the use of solid sorption systems as high-temperature topping cycles can avoid these corrosion problems. The simple connecting of the individual cycles is not sufficient to obtain a significant energy saving. All units of a cascading cycle have to be optimized for the coupling. General considerations for optimisation of cascading cycles are presented. Numerical data for a cascading triple effect system, which is being realized by a French-German cooperation, are presented.
Détails
- Titre original : Neposredno kurjen kaskadni sorpcijski hladilnik./ Direct fired cascading sorption chiller.
- Identifiant de la fiche : 1999-3546
- Langues : Slovène
- Source : Strojniski vestnik - Journal of mechanical Engineering - vol. 44 - n. 7-8
- Date d'édition : 07/1998
- Document disponible en consultation à la bibliothèque du siège de l'IIF uniquement.
Liens
Voir d'autres articles du même numéro (2)
Voir la source
Indexation
-
Improvement of topping-cycle efficiency with an...
- Auteurs : CERKVENIK B., POREDOS A., ZIEGLER F.
- Date : 06/05/2000
- Langues : Slovène
Voir la fiche
-
Systematic approach for the improvement of doub...
- Auteurs : LEE S. W., KIM M. S., JEONG S., et al.
- Date : 21/05/2006
- Langues : Anglais
- Source : ACRA-2006. Proceedings of the 3rd Asian conference on refrigeration and air conditioning.
Voir la fiche
-
EXPERIMENTAL STUDY OF CASCADING ADSORPTION CYCLES.
- Auteurs : DOUSS N., MEUNIER F.
- Date : 1989
- Langues : Anglais
- Source : Chem. Eng. Sci. - vol. 44 - n. 2
Voir la fiche
-
Simulation d'un système frigorifique à absorpti...
- Auteurs : HE J., YANG J.
- Date : 2004
- Langues : Chinois
- Source : Journal of Refrigeration - n. 3
- Formats : PDF
Voir la fiche
-
Thermoeconomic analysis for a new absorption cy...
- Auteurs : SUN H. J., YOU S. J., TU G. B., et al.
- Date : 22/04/2003
- Langues : Anglais
- Source : Cryogenics and refrigeration. Proceedings of ICCR 2003.
Voir la fiche