Régulation auto-optimisante d'une tour de refroidissement pour le fonctionnement efficace de systèmes d'eau glacée.
Self-optimizing control of cooling tower for efficient operation of chilled water systems.
Numéro : pap. 3211
Auteurs : LI X., LI Y., SEEM J. E., et al.
Résumé
The chilled-water systems, mainly consisting of electric chillers and cooling towers, are crucial for the ventilating and air conditioning systems in commercial buildings. Energy efficient operation of such systems is thus important for the energy saving of commercial buildings. This paper presents an extremum seeking control (ESC) scheme for energy efficient operation of the chilled-water system, and presents a Modelica based dynamic simulation model for demonstrating the effectiveness of the proposed control strategy. The simulated plant consists of a water-cooled screw chiller and a mechanical-draft counter-flow wet cooling tower. The ESC scheme takes the total power consumption of the chiller compressor and the tower fan as feedback, and uses the fan speed setting as the control input. The inner-loop controllers for the chiller operation include two proportional-integral (PI) control loops for regulating the evaporator superheat and the chilled water temperature. Simulation was conducted on the dynamic simulation model of the whole plant including the screw chiller and the cooling tower for different scenarios. The simulation results demonstrated the effectiveness of the proposed ESC strategy in searching for the optimal tower fan speed set-point under tested circumstances, and the potential for energy saving is also evaluated.
Documents disponibles
Format PDF
Pages : 10 p.
Disponible
Prix public
20 €
Prix membre*
15 €
* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)
Détails
- Titre original : Self-optimizing control of cooling tower for efficient operation of chilled water systems.
- Identifiant de la fiche : 30006801
- Langues : Anglais
- Source : 2012 Purdue Conferences. 2nd International High Performance Buildings Conference at Purdue.
- Date d'édition : 16/07/2012
Liens
Voir d'autres communications du même compte rendu (42)
Voir le compte rendu de la conférence
-
Tours de refroidissement de l'eau : économie d'...
- Auteurs : GOSI P., HALASZ J., KOSTKA P.
- Date : 1991
- Langues : Hongrois
- Source : Energ. Atomtech. - vol. 44 - n. 5
Voir la fiche
-
THE FORMATION, IMPLICATIONS AND CONTROL OF BIOF...
- Auteurs : SCHAPIRA S.
- Date : 1988
- Langues : Anglais
- Source : Hosp. Eng. - vol. 42 - n. 10
Voir la fiche
-
REFRIGERANTS HUMIDES INDUSTRIELS A TUBES AILETE...
- Auteurs : BLONDEAU M., JANNOT M., VIANNAY S.
- Date : 1983
- Langues : Français
- Source : Rev. gén. Therm. - vol. 22 - n. 257
Voir la fiche
-
POLISHED WATER FIGHTS LEGIONNAIRES' DISEASE.
- Date : 10/1989
- Langues : Anglais
- Source : H&V Eng. - vol. 62 - n. 697
Voir la fiche
-
MEASUREMENT OF COOLING TOWER FILL MATERIAL PERF...
- Auteurs : SCHULTZ T., ERENS P. J.
- Date : 23/04/1990
- Langues : Anglais
Voir la fiche