Réponse thermique en régime stable de régénérateurs à lit fixe en écoulement à contre courant rapidement inversé.

Cyclic steady thermal response of rapidly switched fixed-bed heat regenerators in counterflow.

Auteurs : MONTE F. de

Type d'article : Article

Résumé

An analytical solution of the countercurrent thermal regenerator problem when its cyclic steady state is established is given. It takes account of the flushing phase. The proposed analytical approach is based on a Lagrange frame of reference for evaluating the fluid temperature during an entire operation cycle. This temperature is obtained as a function of the time and location within the regenerator and its profile depends on two dimensionless parameters.

Détails

  • Titre original : Cyclic steady thermal response of rapidly switched fixed-bed heat regenerators in counterflow.
  • Identifiant de la fiche : 2000-0676
  • Langues : Anglais
  • Source : International Journal of Heat and Mass Transfer - vol. 42 - n. 14
  • Date d'édition : 07/1999