Document IIF
Rôle de la zone de latence avant établissement de l'écoulement diphasique des frigorigènes dans un capillaire.
Effect of delay length at the onset of two-phase flow of refrigerant in capillary tube.
Auteurs : GUJRAL I. S., DAVE R. K., GORASIA J. N., et al.
Résumé
This work is confined to the design of straight capillary tubes. Actual vapour bubble formation takes place at a longer tube length than predicted by thermodynamic equilibrium conditions. A transition zone has been denoted by delay length, which occurs when the refrigerant enters into the two-phase region from the liquid region. Delay length plays a very important role. The delayed formation of the actual first bubble results in metastability and is responsible for the development of a transition zone at the onset of flash point. The delay length, as dealt in this paper, is a measure of such a transition zone. The paper discusses the effect of input parameters on delay length. Adiabatic slug flow of CFC-12 with no heat exchanger has been considered.
Documents disponibles
Format PDF
Disponible
Prix public
20 €
Prix membre*
Gratuit
* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)
Détails
- Titre original : Effect of delay length at the onset of two-phase flow of refrigerant in capillary tube.
- Identifiant de la fiche : 2000-1373
- Langues : Anglais
- Source : 20th International Congress of Refrigeration: Refrigeration into the Third Millennium.
- Date d'édition : 19/09/1999
Liens
Voir d'autres communications du même compte rendu (447)
Voir le compte rendu de la conférence
Indexation
-
Thèmes :
CFC;
Ecoulement diphasique;
Supermarchés, meubles de vente - Mots-clés : Écoulement diphasique; Circuit frigorifique; Capillaire; R12
-
Simulation of the effects of oil in capillary t...
- Auteurs : SILVA HUERTA A. A., MATTOS SILVARES O. de
- Date : 14/07/1998
- Langues : Anglais
- Source : Proceedings of the 1998 Purdue International Refrigeration Conference.
Voir la fiche
-
Constitutive equations for capillary tube model...
- Auteurs : MELO C., NETO C. B., FERREIRA R. T. S., PEREIRA R. H.
- Date : 14/07/1998
- Langues : Anglais
- Source : Proceedings of the 1998 Purdue International Refrigeration Conference.
Voir la fiche
-
Performance comparison of cold storage showcase...
- Auteurs : LIU C. C., LIN J. Y., SHYU R. J., et al.
- Date : 19/09/1999
- Langues : Anglais
- Source : 20th International Congress of Refrigeration: Refrigeration into the Third Millennium.
- Formats : PDF
Voir la fiche
-
Accelerated evaluation of capillary clogging in...
- Auteurs : TAIRA S., OONUMA Y., YAMAKAWA K., YAJIMA R.
- Date : 14/07/1998
- Langues : Anglais
- Source : Proceedings of the 1998 Purdue International Refrigeration Conference.
Voir la fiche
-
An homogeneous model for adiabatic capillary tu...
- Auteurs : BANSAL P. K., RUPASINGHE A. S.
- Date : 03/1998
- Langues : Anglais
- Source : Applied Thermal Engineering - vol. 18 - n. 3-4
Voir la fiche