Résumé
In the paper, pressure drop through a capillary tube is modelled in an attempt to predict the size of capillary tubes used in residential air conditioners and also to provide simple correlating equations for practicing engineers. Stoecker's basic model was modified with the consideration of various effects due to subcooling, area contraction, different equations for viscosity and friction factor, and finally mixture effect. McAdam's equation for the two-phase viscosity and Stoecker's equation for the friction factor yielded the best results among various equations. With these equations, the modified model yielded the performance data that are comparable to those in the ASHRAE handbook. After the model was validated with experimental data for CFC-12, HFC-134a, HCFC-22, and R407C, performance data were generated for HCFC-22 and its alternatives, HFC-134a, R407C and R410A under the following conditions: condensing temperature; 40, 45, 50, 55 °C, subcooling: 0, 2.5, 5 °C, capillary tube diameter; 1.2-2.4 mm, mass flow rate; 5-50 g/s. These data showed that the capillary tube length varies uniformly with the changes in condensing temperature and subcooling. Finally, a regression analysis was performed to determine the dependence of mass flow rate on the length and diameter of a capillary tube, condensing temperature, and subcooling. Thus determined simple practical equations yielded a mean deviation of 2.4% for 1488 data obtained for two pure and two mixed refrigerants examined in this study.
Documents disponibles
Format PDF
Pages : 604-614
Disponible
Prix public
20 €
Prix membre*
Gratuit
* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)
Détails
- Titre original : Capillary tube selection for HCFC-22 alternatives.
- Identifiant de la fiche : 2000-0949
- Langues : Anglais
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 22 - n. 8
- Date d'édition : 12/1999
Liens
Voir d'autres articles du même numéro (5)
Voir la source
Indexation
-
Thèmes :
CFC;
Autres équipements de conditionnement d'air;
HCFC;
HFC;
Mélanges - Mots-clés : Circuit frigorifique; R410A; R407C; R134a; Capillaire; Conditionneur d'air; R22; R12
-
Replacements for HCFC-22 in air conditioning an...
- Auteurs : SPATZ M. W.
- Date : 25/07/2000
- Langues : Anglais
- Source : Proceedings of the 2000 International Refrigeration Conference at Purdue.
Voir la fiche
-
A generalized performance prediction method for...
- Auteurs : BITTLE R. R., WOLF D. A., PATE M. B.
- Date : 01/1998
- Langues : Anglais
- Source : HVAC&R Research - vol. 4 - n. 1
Voir la fiche
-
Two-fluid model of refrigerant two-phase flow t...
- Auteurs : YANG L., ZHANG C. L.
- Date : 05/2005
- Langues : Anglais
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 28 - n. 3
- Formats : PDF
Voir la fiche
-
HFC replacement for R22.
- Auteurs : MUIR E. B.
- Date : 21/09/1994
- Langues : Anglais
- Source : CFCs, the Day After.
- Formats : PDF
Voir la fiche
-
A generalized correlation for the characteristi...
- Auteurs : YANG L., WANG W.
- Date : 03/2008
- Langues : Anglais
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 31 - n. 2
- Formats : PDF