Simulation de la chute de pression et optimisation de la taille des tuyaux dans un système frigorifique à ammoniac.
Simulation of pressure drop and optimization of pipe sizes in a refrigerating system with ammonia refrigerant.
Auteurs : ZHUANG Y.
Résumé
Mathematical models for pressure drops through both the suction pipe to compressor and the wet return pipe from evaporator in an ammonia pump feeding refrigeration system were developed. The performance of the system was simulated using a computer program which was developed based on the two pressure drop models and the thermal parameters models of the ammonia refrigerant. An ice making refrigeration loop with the cooling capacity of 100 kW, a 102-meter-long suction pipe and a 152-meter-long wet return pipe, was taken as a target studied. The simulation results show that, compared to the traditional pipe selecting method, the pipe size optimization can increase COP of the system by 7.6%, contributing to electricity saving of 9092 kWh each year. The economic analysis shows the payback period of the additional cost caused by the optimized pipes in the example is less than 2 years. The life period of the refrigerating compressor used in the system can be extended because of the decrease of the discharge temperature after pipe size optimization.
Documents disponibles
Format PDF
Pages : ICR07-D1-289
Disponible
Prix public
20 €
Prix membre*
Gratuit
* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)
Détails
- Titre original : Simulation of pressure drop and optimization of pipe sizes in a refrigerating system with ammonia refrigerant.
- Identifiant de la fiche : 2008-0618
- Langues : Anglais
- Source : ICR 2007. Refrigeration Creates the Future. Proceedings of the 22nd IIR International Congress of Refrigeration.
- Date d'édition : 21/08/2007
Liens
Voir d'autres communications du même compte rendu (839)
Voir le compte rendu de la conférence
Indexation
-
Carbon dioxide: secondary coolant or refrigeran...
- Auteurs : INFANTE FERREIRA C. A., BOUKENS R. A.
- Date : 03/09/1996
- Langues : Anglais
- Source : Applications for Natural Refrigerants
- Formats : PDF
Voir la fiche
-
Presión en componentes de los circuitos frigorí...
- Auteurs : GARCÍA RUÍZ F.
- Date : 12/2006
- Langues : Espagnol
- Source : Frío Clima - n. 52
- Formats : PDF
Voir la fiche
-
Developing flow correlations for different valv...
- Auteurs : STULGIES N., KÖHLER J., TEGETHOFF W., et al.
- Date : 05/2008
- Langues : Anglais
- Source : HVAC&R Research - vol. 14 - n. 3
Voir la fiche
-
Two-phase flow in pipe line systems.
- Auteurs : PRISTOVNIK A., GORICANEC D., KROPE J.
- Date : 09/05/1998
- Langues : Anglais
- Source : Heating and air-conditioning of buildings. Energy and environment. Proceedings of the third SITHOK-3 International Congress + CD-ROM.
Voir la fiche
-
Prediction and simulation of two-phase pressure...
- Auteurs : PADILLA M., REVELLIN R., BONJOUR J.
- Date : 11/2009
- Langues : Anglais
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 32 - n. 7
- Formats : PDF
Voir la fiche