Résumé
There are often abnormal working conditions at evaporator outlet of a refrigeration system, such as two-phase state in transient process, and it is essential to investigate such transient behaviours for system design and control strategy. In this paper, a dynamic lumped parameter model is developed to simulate the transient behaviours of refrigeration system with variable capacity in both normal and abnormal working conditions. The appropriate discriminant method is adopted to switch the normal and abnormal conditions smoothly and to eliminate the simulated data oscillation. In order to verify the dynamic model, we built a test system with variable frequency compressor, water-cooling condenser, evaporator and electronic expansion valve. Calculated values from the mathematical model show reasonable agreement with the experimental data. The simulation results show that the transient behaviours of the variable capacity refrigeration system in the abnormal working conditions can be calculated reliably with the dynamic model when the compressor rotary speed or the opening of electronic expansion valve changes abruptly. [Reprinted with permission from Elsevier. Copyright, 2010].
Détails
- Titre original : Dynamic simulation of variable capacity refrigeration systems under abnormal conditions.
- Identifiant de la fiche : 30001447
- Langues : Anglais
- Source : Applied Thermal Engineering - vol. 30 - n. 10
- Date d'édition : 07/2010
- DOI : http://dx.doi.org/10.1016/j.applthermaleng.2010.01.038
Liens
Voir d'autres articles du même numéro (9)
Voir la source
-
Standardizing data for VFD Efficiency.
- Auteurs : KRUKOWSKI A., WRAY C. P.
- Date : 06/2013
- Langues : Anglais
- Source : ASHRAE Journal - vol. 55 - n. 6
Voir la fiche
-
A study on the use of liquid separators in vari...
- Auteurs : CARVALHO B. Y. K., MELO C., PEREIRA R. H.
- Date : 21/08/2016
- Langues : Anglais
- Source : 12th IIR Gustav Lorentzen Conference on Natural Refrigerants (GL2016). Proceedings. Édimbourg, United Kingdom, August 21st-24th 2016.
- Formats : PDF
Voir la fiche
-
Utilisation de la vitesse variable dans les ate...
- Auteurs : LEDUCQ D., GUILPART J., TRYSTRAM G.
- Date : 21/11/2000
- Langues : Français
- Source : Les économies d'énergie dans le froid en agroalimentaire : de la bonne utilisation des fluides frigorigènes. Journée française du Froid. Recueil des conférences.
Voir la fiche
-
Proper control of HVAC variable speed pumps.
- Auteurs : TILLACK L., RISHEL J. B.
- Date : 11/1998
- Langues : Anglais
- Source : ASHRAE Journal - vol. 40 - n. 11
Voir la fiche
-
Control apropiado de HVAC bombas de velocidad v...
- Auteurs : TILLACK L., RISHEL J. B.
- Date : 12/2001
- Langues : Espagnol
- Source : Frío Calor Aire acondicionado - vol. 29 - n. 332
Voir la fiche