Simulation et validation expérimentale de système à débit de frigorigène variable sous conditions de refroidissement.
Simulation and experimental validation of the variable refrigerant flows system under the cooling conditions.
Résumé
Variable refrigerant flow (VRF) air conditioning system gains widely attentions due to its better energy performance in the part load conditions. However, the outdoor air ventilation capacity of the VRF system is usually not satisfied. A VRF and variable air volume combined air conditioning system is investigated through simulation as a solution for the ventilation problem while taking advantage of its high part load energy efficiency. In the previous study, VRF models of component-number independence were developed. As another part of the study, this paper introduces the work in the experimental validation of simulation models. Firstly, the experimental rig is introduced, which consists of an outdoor unit (including a variable speed compressor and a heat exchanger), two indoor heat exchangers, two electronic expansion valves, pipes and accessories. A constant temperature and humidity room is used to ensure the required inlet conditions for all the heat exchangers. Secondly, the simulation models are validated using the experimental data. The maximum errors for cooling capacity and input power are less than 7%. The maximum relative error of COP is 10.54%. In addition, the control responses of the VRF system under the various conditions are validated. The results show that simulation matches the experiments very well indicating the accurate prediction of the models responding to the varying compressor speed, EEV opening position and evaporator inlet air temperature.
Documents disponibles
Format PDF
Pages : 8 p.
Disponible
Prix public
20 €
Prix membre*
Gratuit
* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)
Détails
- Titre original : Simulation and experimental validation of the variable refrigerant flows system under the cooling conditions.
- Identifiant de la fiche : 30016224
- Langues : Anglais
- Source : Proceedings of the 24th IIR International Congress of Refrigeration: Yokohama, Japan, August 16-22, 2015.
- Date d'édition : 16/08/2015
- DOI : http://dx.doi.org/10.18462/iir.icr.2015.0350
Liens
Voir d'autres communications du même compte rendu (657)
Voir le compte rendu de la conférence
-
Evaluation of VRF system with multi indoor unit...
- Auteurs : MATSUMOTO K., OHNO K., SAITO K.
- Date : 16/08/2015
- Langues : Anglais
- Source : Proceedings of the 24th IIR International Congress of Refrigeration: Yokohama, Japan, August 16-22, 2015.
- Formats : PDF
Voir la fiche
-
A VRF charge fault diagnosis method based on ex...
- Auteurs : YU F., LI G., CHEN H., et al.
- Date : 08/2018
- Langues : Anglais
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 92
- Formats : PDF
Voir la fiche
-
Control analysis of VRF air-conditioners for th...
- Auteurs : MATSUMOTO K., SAITO K., YAMAGUCHI S., et al.
- Date : 24/08/2019
- Langues : Anglais
- Source : Proceedings of the 25th IIR International Congress of Refrigeration: Montréal , Canada, August 24-30, 2019.
- Formats : PDF
Voir la fiche
-
Distributed extremum seeking control for a vari...
- Auteurs : ZHU Y., LI Y., DONG L., et al.
- Date : 11/07/2016
- Langues : Anglais
- Source : 2016 Purdue Conferences. 16th International Refrigeration and Air-Conditioning Conference at Purdue.
- Formats : PDF
Voir la fiche
-
Control and energy simulation of variable refri...
- Auteurs : ZHU Y. H., JIN X. Q., DU Z. M., et al.
- Date : 03/2014
- Langues : Anglais
- Source : Applied Thermal Engineering - vol. 64 - n. 1-2
Voir la fiche