Simulation transitoire d'un écoulement d'air et de la dispersion d'un agent polluant sous écoulement par mélange entraîné par la poussée dans les immeubles résidentiels.

Transient simulation of airflow and pollutant dispersion under mixing flow and buoyancy driven flow regimes in residential buildings.

Auteurs : RIM D. H., NOVOSELAC A.

Résumé

The distribution of airflow in a residential building varies with the periodic operation of a heating, ventilating and air-conditioning (HVAC) system. Depending on the HVAC fan operation, mixing airflow (fan ON) or stratified airflow (fan OFF) occurs in the space. The objectives of this study are: 1) to examine the time needed for room air to stabilize after a central ventilation fan turns ON/OFF; and 2) to evaluate how the difference in distribution of gaseous and particulate pollutants in the space depends on fan operation mode. In the study, experiments measured the spatial distribution of airflow and pollutant concentrations in a full-scale environmental chamber. The measured data then provided the basis to establish a reliable computational fluid dynamics (CFD) model, which investigated the concentrations of gaseous and particulate pollutants depending on the mechanical fan operation mode. The results indicate that the transition between mixing flow and stratified flow occurs in a time scale of seconds, implying that the airflow in residential buildings is primarily mixing or stratified flow. The results show little spatial variation of tracer gas and particles in the mixing flow regime, whereas larger temporal and spatial variations are present in stratified flow. Additionally, the variations in particle concentrations are higher than those in gaseous concentrations. In certain areas of the room the particle concentration with stratified flow is up to thirty times higher than that with mixing flow, implying a high potential of exposure to particles when the fan is OFF.

Détails

  • Titre original : Transient simulation of airflow and pollutant dispersion under mixing flow and buoyancy driven flow regimes in residential buildings.
  • Identifiant de la fiche : 2009-1264
  • Langues : Anglais
  • Source : ASHRAE Transactions. 2008 Annual Meeting, Salt Lake City, UT. Volume 114, part 2 + CD-ROM.
  • Date d'édition : 21/06/2008

Liens


Voir d'autres communications du même compte rendu (24)
Voir le compte rendu de la conférence