Surface de force utile et coefficient de décharge pour les soupapes à lamelles multiples: Un ensemble complet de données tirées d’une étude numérique.
Effective force area and discharge coefficient for reed type valves: A comprehensive data set from a numerical study.
Auteurs : LOPES FERREIRA R., GASCHE J. L.
Type d'article : Article, Article de la RIF
Résumé
Radial diffusers have been used as valve model to determine effective force area and discharge coefficient of the flow. A comprehensive data set of these parameters is lacking in the literature. Here, we present numerical results of these parameters for a wide range of incompressible flow operating conditions. The code OpenFOAM® was used to solve the problem for radial diffusers with diameter ratios ranging from 1.15 to 1.7, Reynolds numbers ranging from 3000 to 50,000, and lifts varying from 0.01 to 1.0. The influence of the diameter ratio on the effective force area is found to be high. There is a decrease of up to 80% for small lifts and an increase of 40% for large lifts, but it has a negligible effect on the discharge coefficient. The influence of the Reynolds number on the discharge coefficient is small, up to 8%, but it is large on the effective force area.
Documents disponibles
Format PDF
Pages : 287-300
Disponible
Prix public
20 €
Prix membre*
Gratuit
* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)
Détails
- Titre original : Effective force area and discharge coefficient for reed type valves: A comprehensive data set from a numerical study.
- Identifiant de la fiche : 30026145
- Langues : Anglais
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 103
- Date d'édition : 07/2019
- DOI : http://dx.doi.org/10.1016/j.ijrefrig.2019.04.017
Liens
Voir d'autres articles du même numéro (28)
Voir la source
Indexation
- Thèmes : Compresseurs
- Mots-clés : Coefficient; Reynolds; Refoulement; Soupape; Simulation; Compresseur
-
CONTRAINTE DYNAMIQUE DU CLAPET DE REFOULEMENT D...
- Auteurs : FUTAKAWA A., NAMURA K., FURUKAWA H.
- Date : 1981
- Langues : Japonais
- Source : Refrigeration - vol. 56 - n. 647
Voir la fiche
-
Linear compressor discharge valve behavior usin...
- Auteurs : HWANG I. S., PARK S. J., OH W., et al.
- Date : 10/2017
- Langues : Anglais
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 82
- Formats : PDF
Voir la fiche
-
Influence of the valve-seat gap on the dynamics...
- Auteurs : BIANCOLIN MOIMAS G., SEVERINO ABREGO A. L., DOMINGUES BUENO D., GASCHE J. L.
- Date : 10/2020
- Langues : Anglais
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 118
- Formats : PDF
Voir la fiche
-
Modeling the stiction effect in automatic compr...
- Auteurs : PIZARRO-RECABARREN R. A., BARBOSA J. R. Jr, DESCHAMPS C. J.
- Date : 11/2013
- Langues : Anglais
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 36 - n. 7
- Formats : PDF
Voir la fiche
-
Bruit d'un clapet de refoulement installé dans ...
- Auteurs : KIM Y. K., KIEM M. K., LEE D., et al.
- Date : 2001
- Langues : Japonais
- Source : Transactions of the Japan Society of Refrigerating and Air Conditioning Engineers - vol. 18 - n. 3
Voir la fiche