SYSTEME D'ISOLATION ETANCHE ET CAPABLE DE SUPPORTER UNE CHARGE POUR UN RESERVOIR SPHERIQUE DE GNL.

EVACUATED LOAD BEARING INSULATION SYSTEM FOR SPHERICAL LNG TANKS.

Auteurs : BRENDENG E.

Résumé

UN SYSTEME ETANCHE D'ISOLATION ET CAPABLE DE SUPPORTER UNE CHARGE A ETE UTILISE POUR L'ISOLATION D'UN RESERVOIR D'ESSAI DE 2 M DE DIAMETRE. LA CONDUCTION DE CHALEUR A ETE ETABLIE PAR DES MESURES DE FUITES PAR EBULLITION DU RESERVOIR, AVEC DIFFERENTES PRESSIONS DANS L'ISOLATION. DE L'AZOTE LIQUIDE A ETE UTILISE DANS LE RESERVOIR POUR CES EXPERIENCES. LA CONCEPTION DU JOINT D'ETANCHEITE NE S'EST PAS REVELEE SATISFAISANTE. LA POROSITE DES SOUDURES RENDAIT IMPOSSIBLE L'OBTENTION, DANS LA CHAMBRE D'ISOLATION, D'UNE PRESSION SUFFISAMMENT BASSE ET DONC D'UNE CONDUCTIVITE SUFFISAMMENT FAIBLE ; LE MANQUE DE SOUPLESSE ENTRAINAIT L'ECRASEMENT LOCALISE DE LA STRUCTURE D'ISOLATION. CEPENDANT, LES MESURES DE CONDUCTIVITE CORRESPONDAIENT BIEN AVEC LES PREVISIONS.

Détails

  • Titre original : EVACUATED LOAD BEARING INSULATION SYSTEM FOR SPHERICAL LNG TANKS.
  • Identifiant de la fiche : 1991-0988
  • Langues : Anglais
  • Date d'édition : 17/10/1989
  • Source : Source : Proc. LNG 9 GNL, Nice
    vol. 2; sess. 4; n. 6; 10 p.; 5 fig.; 2 tabl.; 3 ref.
  • Document disponible en consultation à la bibliothèque du siège de l'IIF uniquement.