Système expérimental et intégré de pompe à chaleur à absorption pour le traitement des eaux usées. 1. Fonctionnement avec des solutions d'eau-bromure de lithium.

An experimental integrated absorption heat pump effluent purification system. 1. Operating on water-lithium bromide solutions.

Auteurs : SANTOYO-GUTIÉRREZ S., SIQUEIROS J., HEARD C. L., et al.

Type d'article : Article

Résumé

The merits of single-stage absorption heat pumps coupled to simple distillation for effluent treatment are discussed. An experimental integrated absorption heat pump effluent purification system was built and operated with water-lithium bromide as a working mixture. Pure effluent production rates of between 0.5 and 4.3 kg/h were obtained. The actual COP and the heat pump effectiveness varied from 1.1 to 1.4 and 0.58 to 0.72, respectively.

Détails

  • Titre original : An experimental integrated absorption heat pump effluent purification system. 1. Operating on water-lithium bromide solutions.
  • Identifiant de la fiche : 2000-2188
  • Langues : Anglais
  • Source : Applied Thermal Engineering - vol. 19 - n. 5
  • Date d'édition : 05/1999

Liens


Voir d'autres articles du même numéro (2)
Voir la source