Systèmes utilisés pour les conteneurs frigorifiques maritimes : régulation intelligente pour réduire la surchauffe et optimiser la performance de l'évaporateur.

Intelligent control to reduce superheat hunting and optimize evaporator performance in container refrigeration.

Auteurs : JOLLY P. G., TSO C. P., CHIA P. K., et al.

Type d'article : Article

Résumé

Fuzzy logic is applied to the control of superheat in the evaporator of a commercial container refrigeration system using an electronic expansion valve and adaptive superheat control algorithm has been devised to enhance evaporator performance. Superheat hunting has been reduced, and an improvement of 7.5% in the coefficient of performance of the refrigeration system can be realized.

Détails

  • Titre original : Intelligent control to reduce superheat hunting and optimize evaporator performance in container refrigeration.
  • Identifiant de la fiche : 2001-2499
  • Langues : Anglais
  • Source : HVAC&R Research - vol. 6 - n. 3
  • Date d'édition : 07/2000
  • Document disponible en consultation à la bibliothèque du siège de l'IIF uniquement.

Liens


Voir d'autres articles du même numéro (3)
Voir la source