Document IIF

Theoretical investigation on the energetic and exergetic performance improvement method of the high temperature transcritical CO2 heat pump with two-stage expander.

Auteurs : JIANG L., CHANG T., LI S., SONG Y., CUI C., CAO F., WANG X.

Type d'article : Article de la RIF

Résumé

Coastal industries (e.g., food processing, chemical distillation), commercial facilities, and residential buildings demand high-temperature heat supply (90–140 ◦C). Conventional air-source heat pumps were limited to below 80 ◦C, while transcritical CO₂ seawater-source heat pumps offered a viable pathway by leveraging abundant seawater. However, existing systems suffered from suboptimal expansion work recovery and severe exergy destruction when the water outlet temperature exceeded 120 ◦C. This paper proposed a novel two-stage expander system (TSES) that closely matched the entire expansion process of the transcritical CO2 cycle, enabling efficient cascade energy recovery. Consequently, TSES overcame the operating range limitations of single-stage turbine system (STES) and single-stage volumetric expander systems (SVES). Thermodynamic modeling and performance comparisons demonstrated that TSES delivered clear advantages across typical seawater-source heating conditions. For instance, for gas-cooler inlet water temperatures between 35 ◦C and 60 ◦C, the heating coefficient of performance (COP) and exergy efficiency of the TSES consistently outperformed those of the single-stage expander systems by roughly 2%. Its relative improvement grew further with rising inlet water temperature, maintaining a lead of >8% over the reference systems at 60 ◦C. Furthermore, in the high-temperature heating region with gas-cooler outlet water temperature of 120–140 ◦C, the COP and exergy efficiency advantages of the TSES over the STES gradually widened from 2.71% to 6.27%, while its advantage over the SVES remained consistently above 8%. These gains stemmed from structural improvements: the TSES reduced the expansion exergy destruction share by over 30% and increased expansion work recovery rate by over 60% relative to both single-stage systems.

Documents disponibles

Format PDF

Pages : 14 p.

Disponible

  • Prix public

    20 €

  • Prix membre*

    Gratuit

* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)

Détails

  • Titre original : Theoretical investigation on the energetic and exergetic performance improvement method of the high temperature transcritical CO2 heat pump with two-stage expander.
  • Identifiant de la fiche : 30035519
  • Langues : Anglais
  • Sujet : Technologie
  • Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 191
  • Date d'édition : 11/2026
  • DOI : http://dx.doi.org/https://doi.org/10.1016/j.ijrefrig.2026.107093