Document IIF

Transfert de chaleur côté air et chute de pression dans les condenseurs à serpentin.

Air-side heat transfer and pressure drop in spiral wire-on-tube condensers.

Auteurs : BARBOSA J. R. Jr, SIGWALT R. A.

Type d'article : Article, Article de la RIF

Résumé

The air-side thermal-hydraulic performance of spiral wire-on-tube condensers is investigated experimentally in this paper. Sixteen prototypes have been manufactured and tested in an open-loop wind tunnel calorimeter. The influence of the following geometric parameters has been evaluated: the number of tube passes, the radial and longitudinal tube spacings and the wire spacing. Measurements of the air-side thermal conductance and pressure drop were carried out for air flow rates ranging from 70 to 220 m3/h. The data were correlated using empirical relationships for the Colburn j-factor and the Darcy friction factor. The agreement with the experimental data presented root mean square deviations of 0.9% for the air-side heat transfer and 1.3% for the frictional pressure drop dimensionless parameters. A quantitative analysis based on the core volume goodness factors for heat transfer and pressure drop is presented to provide the most viable configuration from the point of view of application in a refrigerator.

Documents disponibles

Format PDF

Pages : 939-951

Disponible

  • Prix public

    20 €

  • Prix membre*

    Gratuit

* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)

Détails

  • Titre original : Air-side heat transfer and pressure drop in spiral wire-on-tube condensers.
  • Identifiant de la fiche : 30004109
  • Langues : Anglais
  • Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 35 - n. 4
  • Date d'édition : 06/2012

Liens


Voir d'autres articles du même numéro (45)
Voir la source