AUGMENTED HEAT TRANSFER IN SQUARE CHANNELS WITH PARALLEL, CROSSED, AND V-SHAPED ANGLED RIBS.

Auteurs : HAN J. C., EHANG Y. M., LEE C. P.

Type d'article : Article

Résumé

ON A ETUDIE L'EFFET DE L'ANGLE ENTRE LES NERVURES ET LA PAROI SURLES DISTRIBUTIONS DU TRANSFERT DE CHALEUR LOCAL ET SUR LA PERTE DE PRESSION, DANS UN CANAL CARRE CONSTITUE DE 2 PAROIS OPPOSEES NERVUREES. L'ETUDE A ETE EFFECTUEE A DES NOMBRES DE REYNOLDS COMPRIS ENTRE 15.000 ET 90.000. LE CANAL CARRE SE COMPOSE DE 10 SECTIONS EN CUIVRE ISOLEES. ON A ETUDIE 9 CONFIGURATIONS DE NERVURES. LES RESULTATS ONT REVELE QUE DES NERVURES EN FORME DE V PLACEES A UN ANGLE DE 60 OU DE 45 DEG AVEC LA PAROI PERMETTAIENT UNE MEILLEURE PERFORMANCE QUE LES NERVURES PARALLELES PLACEES A UN ANGLE DE 60 OU DE 45 DEG AVEC LA PAROI ET, PAR CONSEQUENT, MEILLEURE EGALEMENT A CELLE DES NERVURES EN CROIX A UN ANGLE DE 60 OU DE 45 DEG ET DES NERVURES PLACEES A UN ANGLE DE 90 DEG. C'EST AVEC LES NERVURES EN CROIX QUE L'INTENSIFICATION DU TRANSFERT DE CHALEUR A ETE LA PLUS FAIBLE ET LA PERTE DE PRESSION LA PLUS FAIBLE.

Détails

  • Titre original : AUGMENTED HEAT TRANSFER IN SQUARE CHANNELS WITH PARALLEL, CROSSED, AND V-SHAPED ANGLED RIBS.
  • Identifiant de la fiche : 1992-1580
  • Langues : Anglais
  • Source : J. Heat Transf. - vol. 113 - n. 3
  • Date d'édition : 08/1991