TRANSFERT THERMIQUE TURBULENT ET FROTTEMENT POUR DES FILS HELICOIDAUX INSERES DANS DES TUBES.

TURBULENT FLOW HEAT TRANSFER AND FLUID FRICTION IN HELICAL-WIRE-COIL-INSERTED TUBES.

Auteurs : SETHUMADHAVAN R., RAJA RAO M.

Type d'article : Article

Résumé

ON PRESENTE DES RESULTATS EXPERIMENTAUX DE TRANSFERT DE CHALEUR DANS DES TUBES EN CUIVRE DE DIAMETRE INTERIEUR 25 MM, MUNIS DE TURBULATEURS CONSTITUES DE FIL ENROULE EN HELICE AVEC UN PAS, UN ANGLE D'HELICE ET UN DIAMETRE DE FIL DEFINIS. UNE LOI DE SIMILITUDE PERMET D'INTERPRETER LES RESULTATS RELATIFS AU FROTTEMENT ET AU TRANSFERT THERMIQUE ET DE LES CORRELER EN TERME DE RUGOSITE POUR LE NOMBRE DE REYNOLDS FONCTION DE QUANTITE DE MOUVEMENT ET FONCTION DU TRANSFERT DE CHALEUR. CES RESULTATS SONT COMPARES AVEC LES RESULTATS DE LA BIBLIOGRAPHIE. UNE FORMULE GENERALE EST DEVELOPPEE ET EST APPLICABLE POUR DIFFERENTS TYPES DE SURFACES RUGUEUSES. UNE ETUDE D'OPTIMISATION EST FAITE POUR MAXIMALISER LE TRANSFERT THERMIQUE ET REDUIRE LA PUISSANCE DE POMPAGE AFIN D'IDENTIFIER LE TUBE LE PLUS EFFICACE.

Détails

  • Titre original : TURBULENT FLOW HEAT TRANSFER AND FLUID FRICTION IN HELICAL-WIRE-COIL-INSERTED TUBES.
  • Identifiant de la fiche : 1985-0073
  • Langues : Anglais
  • Source : International Journal of Heat and Mass Transfer - vol. 26 - n. 12
  • Date d'édition : 12/1983

Liens


Voir d'autres articles du même numéro (4)
Voir la source