Un détendeur à vapeur pour un cycle à récupération de chaleur.

A steam expander for a waste heat recovery cycle.

Numéro : pap. n. R5, 2263

Auteurs : KIM H. J., KIM Y. C.

Résumé

A steam expander has been studied for its usability as a power conversion device in a Rankine cycle, which can be used for on-site power generation or waste heat recovery. Design of a swash plate type expander has been practiced and its performance has been estimated. With the steam pressure and temperature of 3.5 MPa and 300°C at the expander inlet, respectively, it was calculated that the expander produced the shaft poweroutput of about 2.88 kW from the steam heat source of 25 kW. The expander output increased lonearly with increasing the steam heat amount. For a given steam heat amount, the expander power increased with increasing the inlet steam temperature and it was not affected much by the inlet steam pressure. The expander efficiency was more or less constant at around 75%, regardless of the steam condition at the expander inlet.

Documents disponibles

Format PDF

Pages : 7 p.

Disponible

  • Prix public

    20 €

  • Prix membre*

    15 €

* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)

Détails

  • Titre original : A steam expander for a waste heat recovery cycle.
  • Identifiant de la fiche : 30000553
  • Langues : Anglais
  • Source : 2010 Purdue Conferences. 13th International Refrigeration and Air-Conditioning Conference at Purdue.
  • Date d'édition : 12/07/2010

Liens


Voir d'autres communications du même compte rendu (121)
Voir le compte rendu de la conférence