Un échangeur de chaleur à surface augmentée grâce à une conception d'ailettes segmentées.
Enhanced heat exchanger with an offset spine fin design.
Numéro : pap. 2252
Auteurs : KEMPIAK M. J., JUNGE B.
Résumé
Spine (segmented) fin coils have been used in certain applications as a result of their effective use of coil material. One can improve coil heat transfer performance by adding more fins per inch (FPI). This comes at the expense of air side pressure drop, which requires more fan energy to achieve the same air flow. When this type of fin is used in an evaporator, there is a secondary penalty associated with the fan heat that must be removed by the refrigeration system. Also, the tighter fin spacing is less tolerant to frost growth that can block air flow over time. The current research focuses on a new configuration that nearly doubles the surface area of the fins, yet has similar fin spacing. Performance is evaluated using one inch sections of the tube and fins. The air side pressure drop is measured and thermal performance is evaluated using a transient thermal imaging technique developed for low velocity airflows. The conductance of the offset fin is increased 30% relative to the traditional spine fin design and also has a 30% higher air-side pressure.
Documents disponibles
Format PDF
Pages : 10 p.
Disponible
Prix public
20 €
Prix membre*
15 €
* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)
Détails
- Titre original : Enhanced heat exchanger with an offset spine fin design.
- Identifiant de la fiche : 30013480
- Langues : Anglais
- Source : 2014 Purdue Conferences. 15th International Refrigeration and Air-Conditioning Conference at Purdue.
- Date d'édition : 14/07/2014
Liens
Voir d'autres communications du même compte rendu (203)
Voir le compte rendu de la conférence
Indexation
-
Thèmes :
Evaporateurs, condenseurs et autres échangeurs thermiques;
Transfert de chaleur;
Circulation du fluide : tuyauterie, régulation, automatisme, sécurité - Mots-clés : Coefficient de transfert de chaleur; Ailette; Tube; Conception; Air; Experimentation; Écoulement; Échangeur de chaleur; Chute de pression
-
A new generation of ammonia unit coolers.
- Auteurs : FILIPPINI S., MERLO U.
- Date : 07/05/2009
- Langues : Anglais
- Source : 3th Conference on Ammonia Refrigeration Technology. Proceedings: Ohrid, North Macedonia, May 7-9, 2009.
- Formats : PDF
Voir la fiche
-
Nueva generación de refrigeradores de unidades ...
- Auteurs : FILIPPINI S., MERLO U.
- Date : 06/2010
- Langues : Espagnol
- Source : IIF-IIR/Frío Calor Aire acond. - vol. 38 - n. 426
- Formats : PDF
Voir la fiche
-
DESIGN AND OPTIMIZATION OF AIR-COOLED HEAT EXCH...
- Auteurs : HEDDERICH C. P., KELLEHER M. D., VANDERPLAATS G. N.
- Date : 11/1982
- Langues : Anglais
- Source : J. Heat Transf. - vol. 104 - n. 4
Voir la fiche
-
Experimental investigation of header configurat...
- Auteurs : JIAO A., ZHANG R., JEONG S.
- Date : 07/2003
- Langues : Anglais
- Source : Applied Thermal Engineering - vol. 23 - n. 10
Voir la fiche
-
Experimental investigations of the single-phase...
- Auteurs : LI W., HRNJAK P.
- Date : 24/08/2019
- Langues : Anglais
- Source : Proceedings of the 25th IIR International Congress of Refrigeration: Montréal , Canada, August 24-30, 2019.
- Formats : PDF
Voir la fiche