Un nouveau type de pompe à chaleur utilisée pour le chauffage d'eau sanitaire : analyse de la performance sous des conditions variables.
A novel heat pump water heater performance analysis at variable conditions.
Auteurs : LIN H. W., NIAN S. H., CHAO L. Y.
Résumé
The purpose of this study was to find the performance at variable climate conditions for the R410A heat pump water heater system, and the test method followed the standard of the JRA4050. The compressor operating frequency, evaporator and condenser operating models were judged according to the variable operating temperature and pressure. From the experimental results, this system had 8 kW heating capacity and the coefficient of performance was equal to 4.0 at dry-bulb temperature at 25°C climate condition. The condensing temperature was kept in 55°C when the hot water outlet temperature was 65°C. At the hot water outlet temperature The degree of the subcooling was large as well as the cold water inlet temperature was low. However, it will have a problem of liquid compression when the subcooling value was large. On the other hand, evaporator had a big pressure drop at the winter climate condition. The condenser water inlet temperature limiting the condenser refrigerant outlet, a decrease in system capacity and COP was seen with an increase in condenser water inlet temperature. Some of information could be get from those system measuring, An excellent performance would be occurred when the cold water inlet temperature was kept as low as possible, the evaporator could get more heat if the surrounding temperature was high, at the same time, the pressure drop between compressor inlet and outlet could be down, the work was generated by compressor could be decreased also, and the system performance could be increased.
Documents disponibles
Format PDF
Disponible
Prix public
20 €
Prix membre*
15 €
* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)
Détails
- Titre original : A novel heat pump water heater performance analysis at variable conditions.
- Identifiant de la fiche : 2011-0328
- Langues : Anglais
- Source : IIR/Eurotherm sustainable refrigeration and heat pump technology conference. Proceedings of the Eurotherm Seminar No. 88, Stockholm, Sweden, June 13-16, 2010.
- Date d'édition : 13/06/2010
Liens
Voir d'autres communications du même compte rendu (49)
Voir le compte rendu de la conférence
Indexation
-
Evaluation de l'efficacité d'un cycle de pompe ...
- Auteurs : SAIKAWA M., HASHIMOTO K.
- Date : 2001
- Langues : Japonais
- Source : Transactions of the Japan Society of Refrigerating and Air Conditioning Engineers - vol. 18 - n. 3
Voir la fiche
-
Investigation on CO2 hybrid ground-coupled heat...
- Auteurs : JIN Z., EIKEVIK T. M., NEKSÅ P., et al.
- Date : 02/2016
- Langues : Anglais
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 62
- Formats : PDF
Voir la fiche
-
Air source heat pumps for temperate and for Nor...
- Auteurs : PEARSON S. F., SMALL A. D.
- Date : 21/08/2011
- Langues : Anglais
- Source : Proceedings of the 23rd IIR International Congress of Refrigeration: Prague, Czech Republic, August 21-26, 2011. Overarching theme: Refrigeration for Sustainable Development.
- Formats : PDF
Voir la fiche
-
Development and experimental analysis of CO2 he...
- Auteurs : TRINCHIERI R., NICOLANDREA C., ROVELLA P.
- Date : 21/08/2016
- Langues : Anglais
- Source : 12th IIR Gustav Lorentzen Conference on Natural Refrigerants (GL2016). Proceedings. Édimbourg, United Kingdom, August 21st-24th 2016.
- Formats : PDF
Voir la fiche
-
Modeling, analysis and energy optimization of a...
- Auteurs : MASIP X., CAZORLA-MARÍN A., MONTAGUD C., et al.
- Date : 19/06/2018
- Langues : Anglais
- Source : CYTEF 2018. IX Congreso Ibérico y VII Congreso Iberoamericano de Ciencias y Técnicas del Frío, Valencia, España, 19-21 junio 2018.
- Formats : PDF
Voir la fiche