UN SYSTEME COMMANDE PAR ORDINATEUR POUR LA MESURE DES TAUX DE RENOUVELLEMENT D'AIR DES BATIMENTS A L'AIDE D'HEXAFLUORURE DE SOUFRE COMME GAZ TRACEUR.

A COMPUTER-CONTROLLED SYSTEM FOR MEASURING BUILDING AIR EXCHANGE RATES USING SULPHUR HEXAFLUORIDE AS A TRACER GAS.

Résumé

ON DECRIT UN SYSTEME COMMANDE PAR ORDINATEURPOUR LA MESURE DES TAUX DE RENOUVELLEMENT D'AIR DANS LES IMMEUBLES. CE SYSTEME CONSISTE EN UN APPAREIL DE SAISIE DES DONNEES COMMANDE PAR UN ORDINATEUR PERSONNEL, UN CHROMATOGRAPHE A PHASE GAZEUSE MUNI D'UNE COLONNE A TAMIS MOLECULAIRE ET UN DETECTEUR A CAPTURE D'ELECTRONS AU SCANDIUM-TRITIUM, UNE STATION METEOROLOGIQUE ET UN ANALYSEUR DE DIOXYDE DE CARBONE. CE SYSTEME PEUT MONITORER JUSQU'A 16 EMPLACEMENTS DIFFERENTS, S'ETALONNANT AUTOMATIQUEMENT ET AFFICHANT LES TAUX DE VENTILATION A LA FIN DE LA PERIODE DE PRELEVEMENT. L'OXYGENE NE PEUT PENETRER DANS LE DETECTEUR A CAPTURE D'ELECTRONS, REDUISANT AINSI LE TEMPS ENTRE LES PRELEVEMENTS ET PROLONGEANT LA DUREE DE VIE DU DETECTEUR.

Détails

  • Titre original : A COMPUTER-CONTROLLED SYSTEM FOR MEASURING BUILDING AIR EXCHANGE RATES USING SULPHUR HEXAFLUORIDE AS A TRACER GAS.
  • Identifiant de la fiche : 1988-2425
  • Langues : Anglais
  • Date d'édition : 08/1987
  • Source : Source : Proc. Indoor Air '87, Berl.
    vol. 3; 165-169; 1 fig.; 5 ref.