Un système de conditionnement d'air alternatif avec une charge thermique latente/sensible découplée.
An alternative air-conditioning system with a sensible-latent decoupled thermal load.
Numéro : pap. 77
Auteurs : NÓBREGA C. E. L., PARISE J. A. R.
Résumé
In the air-conditioning design process, whenever the condition line is significantly steep, it becomes difficult to design a cooling coil whose characteristic process line is able to intersect the condition line at any point, making it impossible to reach a supply air condition. Accordingly, the usual design practice is to overcool the air stream below the desired supply air dry-bulb temperature, so as to accomplish the desired level of humidity. The overcooled air stream is then re-heated up to the desired supply air temperature level, usually by an electricity-driven heating coil. The proposed cycle uses a desiccant wheel and a cooling coil, allowing the thermal load to be decoupled. A numerical simulation of the proposed cycle suggests encouraging results regarding the efficiency of the cooling process.
Documents disponibles
Format PDF
Pages : 11 p.
Disponible
Prix public
20 €
Prix membre*
15 €
* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)
Détails
- Titre original : An alternative air-conditioning system with a sensible-latent decoupled thermal load.
- Identifiant de la fiche : 30008572
- Langues : Anglais
- Source : Clima 2013. 11th REHVA World Congress and 8th International Conference on Indoor Air Quality, Ventilation and Energy Conservation in Buildings.
- Date d'édition : 16/06/2013
Liens
Voir d'autres communications du même compte rendu (424)
Voir le compte rendu de la conférence
-
Numerical simulation of rotary desiccant dehumi...
- Auteurs : JANI D. B., MISHRA M., SAHOO P. K.
- Date : 16/08/2015
- Langues : Anglais
- Source : Proceedings of the 24th IIR International Congress of Refrigeration: Yokohama, Japan, August 16-22, 2015.
- Formats : PDF
Voir la fiche
-
Performance analysis of desiccant dehumidificat...
- Auteurs : JEONG J., YAMAGUCHI S., SAITO K., et al.
- Date : 06/2011
- Langues : Anglais
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 34 - n. 4
- Formats : PDF
Voir la fiche
-
Développement et validation d'un modèle de simu...
- Auteurs : YAMAGUCHI S., SAITO K.
- Date : 2012
- Langues : Japonais
- Source : Transactions of the Japan Society of Refrigerating and Air Conditioning Engineers - vol. 29 - n. 1
Voir la fiche
-
Performance analysis of four-partition desiccan...
- Auteurs : JEONG J., YAMAGUCHI S., SAITO K., et al.
- Date : 05/2010
- Langues : Anglais
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 33 - n. 3
- Formats : PDF
Voir la fiche
-
Study on the efficient drive of a desiccant air...
- Auteurs : JEONG J. S., HORIUCHI Y., HYUN S. G., et al.
- Date : 04/12/2002
- Langues : Anglais
- Source : Green breeze from Asia: frontiers of refrigerants, heat transfer and system.. ACRA-2002. Proceedings of the Asian conference on refrigeration and air conditioning.
Voir la fiche