Un système de conditionnement d'air alternatif avec une charge thermique latente/sensible découplée.
An alternative air-conditioning system with a sensible-latent decoupled thermal load.
Numéro : pap. 77
Auteurs : NÓBREGA C. E. L., PARISE J. A. R.
Résumé
In the air-conditioning design process, whenever the condition line is significantly steep, it becomes difficult to design a cooling coil whose characteristic process line is able to intersect the condition line at any point, making it impossible to reach a supply air condition. Accordingly, the usual design practice is to overcool the air stream below the desired supply air dry-bulb temperature, so as to accomplish the desired level of humidity. The overcooled air stream is then re-heated up to the desired supply air temperature level, usually by an electricity-driven heating coil. The proposed cycle uses a desiccant wheel and a cooling coil, allowing the thermal load to be decoupled. A numerical simulation of the proposed cycle suggests encouraging results regarding the efficiency of the cooling process.
Documents disponibles
Format PDF
Pages : 11 p.
Disponible
Prix public
20 €
Prix membre*
15 €
* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)
Détails
- Titre original : An alternative air-conditioning system with a sensible-latent decoupled thermal load.
- Identifiant de la fiche : 30008572
- Langues : Anglais
- Source : Clima 2013. 11th REHVA World Congress and 8th International Conference on Indoor Air Quality, Ventilation and Energy Conservation in Buildings.
- Date d'édition : 16/06/2013
Liens
Voir d'autres communications du même compte rendu (424)
Voir le compte rendu de la conférence
-
Potential study of desiccant wheel-based water ...
- Auteurs : GLÜCK C., ROLDAN BLASCO E., LENZ B., et al.
- Date : 06/04/2011
- Langues : Anglais
- Source : Sources/sinks Alternative to the Outside Air for Heat Pump and Air-conditioning Techniques (Alternative Sources - AS), Padua, Italy, April 5-7, 2011. / International Sorption Heat Pump Conference (ISHPC11), Padua, Italy, April 6-8, 2011.
- Formats : PDF
Voir la fiche
-
Experimental analysis on the performances of a ...
- Auteurs : ANGRISANI G., MINICHIELLO F., ROSELLI C., et al.
- Date : 06/04/2011
- Langues : Anglais
- Source : Sources/sinks Alternative to the Outside Air for Heat Pump and Air-conditioning Techniques (Alternative Sources - AS), Padua, Italy, April 5-7, 2011. / International Sorption Heat Pump Conference (ISHPC11), Padua, Italy, April 6-8, 2011.
- Formats : PDF
Voir la fiche
-
Modelling and parametric analysis of silica-gel...
- Auteurs : NARAYANAN R., SAMAN W. Y., WHITE S. D., et al.
- Date : 12/04/2010
- Langues : Anglais
- Source : 9th IIR-Gustav Lorentzen Conference on Natural Working Fluids (GL2010). Proceedings. Sydney, Australia, April 12-14, 2010.
- Formats : PDF
Voir la fiche
-
Desiccant dewpoint cooling system independent o...
- Auteurs : BELLEMO L., ELMEGAARD B., MARKUSSEN W. B., et al.
- Date : 16/08/2015
- Langues : Anglais
- Source : Proceedings of the 24th IIR International Congress of Refrigeration: Yokohama, Japan, August 16-22, 2015.
- Formats : PDF
Voir la fiche
-
Numerical simulation of rotary desiccant dehumi...
- Auteurs : JANI D. B., MISHRA M., SAHOO P. K.
- Date : 16/08/2015
- Langues : Anglais
- Source : Proceedings of the 24th IIR International Congress of Refrigeration: Yokohama, Japan, August 16-22, 2015.
- Formats : PDF
Voir la fiche