UNE ETUDE DE SENSIBILITE DES EFFETS DES COEFFICIENTS D'ACCOMMODATION EVAPORATION/CONDENSATION SUR LA MODELISATION TRANSITOIRE DES CALODUCS.

A SENSITIVITY STUDY OF THE EFFECTS OF EVAPORATION/CONDENSATION ACCOMMODATION COEFFICIENTS ON TRANSIENT HEAT PIPE MODELLING.

Auteurs : HALL M. L., DOSTER J. M.

Type d'article : Article

Résumé

LE COMPORTEMENT DYNAMIQUE DES MODELES DE CALODUCS A METAL LIQUIDE EST FORTEMENT INFLUENCE PAR LE CHOIX DES TECHNIQUES DE MODELISATION DE L'EVAPORATION ET DE LA CONDENSATION. LES DESCRIPTIONS DE LA THEORIE CINETIQUE CLASSIQUE DE L'EVAPORATION ET DE LA CONDENSATION SONT SOUVENT INADEQUATES POUR LES SITUATIONS REELLES. LES GEOMETRIES COMPLEXES ET LES CHAMPS D'ECOULEMENT DANS LES SYSTEMES PROPOSES DE CALODUC CAUSENT UNE DEVIATION IMPORTANTE PAR RAPPORT AUX MODELES CLASSIQUES. LE CODE THRHU QUI A ETE DECRIT DANS DES TRAVAUX ANTERIEURS, EST DEVELOPPE POUR MODELISER LE COMPORTEMENT VARIABLE D'UN CALODUC A METAL LIQUIDE A PARTIR DES CONDITIONS DE DEPART JUSQU'AU FONCTIONNEMENT PERMANENT DE PLEINE PUISSANCE.

Détails

  • Titre original : A SENSITIVITY STUDY OF THE EFFECTS OF EVAPORATION/CONDENSATION ACCOMMODATION COEFFICIENTS ON TRANSIENT HEAT PIPE MODELLING.
  • Identifiant de la fiche : 1990-1851
  • Langues : Anglais
  • Source : International Journal of Heat and Mass Transfer - vol. 33 - n. 3
  • Date d'édition : 03/1990

Liens


Voir d'autres articles du même numéro (1)
Voir la source